Question: [Mach3 USB Interface Board] Is there any information on connecting and setting up a pendant.

Current Solution

I would recommend using a wireless pendant, like here: https://amzn.to/49nAjkg (Affiliate link)

I use this pendant on my machine and works quite well. If you have communication issues from the pendant to the dongle, there may be too much interference surrounding the dongle, and exposing the internal antenna works well. This is something I needed to do.

Respond:

Other Possible Solutions to this Question

  • Are there any videos or other sources of information on assembling the greenBull v2?

    The assembly instructions for the greenBull v2 are through an instruction set emailed to the customer that purchased the machine kit.

    Click the link to add information to this solution:
    Are there any videos or other sources of information on assembling the greenBull v2?

  • Are there any special instructions regarding connecting water lines to the 2.2k spindle?

    There is no specific manner in connecting the water lines to the spindle. No specific output and input locations, only the diameter which we use is 1/4 Inside Diameter and 3/8 Outside Diameter (you might find another one that works just as well).
    Unscrew the 2 hose nuts and feed the tube through (will be snug), and adjust the tube on the hose fittings and screw the hose nuts down. Feed the tubes through your machine towards the water bucket, making sure it will not get caught on any moving parts and cause a jam/leak, and fit one tube to the outlet of your water pump and leave the other tube to the bucket as a return line. (unless you are using a cooler like a radiator, then feed it to the outlet of the radiator and to your water pump)

    Click the link to add information to this solution:
    Are there any special instructions regarding connecting water lines to the 2.2k spindle?

  • WHERE CAN I GET INFORMATION ON INFLUENZA (THE FLU) AND ITS SURVEILLANCE?

    Information regarding influenza surveillance is available October through May from the CDC influenza website at www.cdc.gov/flu/weekly/fluactivity.htm.

    In addition, periodic updates about influenza are published in the MMWR. State and local health departments should be consulted regarding availability of influenza vaccine, access to vaccination programs, information about state or local influenza activity, and for reporting influenza outbreaks and receiving advice regarding their control.

    Click the link to add information to this solution:
    WHERE CAN I GET INFORMATION ON INFLUENZA (THE FLU) AND ITS SURVEILLANCE?

  • I need info on connecting my vfd to run via mach3. Any videos please? Thanks.

    I will be making a video on controlling the VFD via Mach3 shortly.

    Click the link to add information to this solution:
    I need info on connecting my vfd to run via mach3. Any videos please? Thanks.

  • I am getting that radus error in Mach3 and changing my IJ setting is not working. Any suggestions?

    What is the actual error that you are seeing in Mach3 and what CAM program are you using? Did you try installing a later version of Mach3 if your's is an earlier version? What post-processing setting are you using in your CAM program?

    Click the link to add information to this solution:
    I am getting that radus error in Mach3 and changing my IJ setting is not working. Any suggestions?

  • THEY ARE ASKING FOR THE ACTIVATION CODE AND SERIAL NUMBER USB BOARD. HOW CAN GET THAT INFORMATION?

    To get the activation code, all you need to do is plug the USB board into the computer using a USB cable, go to machine -> firmware -> update. After the firmware is updated the program will present to you a dialog box containing the activation code.

    Additional Information:
    MUAR-QVXU-CAYW-CBWQ


    Additional Information:
    MUIS-RQPB-PTHB-QTTB

    Additional Information:
    MUIH-EERP-IADB-TRIP

    Additional Information:
    9zYWBVf5TxKSK7hEr8gFX3EBw5wa0AMMllQqgftIAnKvZ8DXItLxaPbOB3jWvnpczl/sM/De0scRPHfSxWGmcA==

    Additional Information:
    Key: LUQR-BQYI-SCEW-QVBT

    Additional Information:


    Additional Information:
    after i copy the code in the lower case i recived the same message (more than 8 times) ,, this is a evaluation...,, what i need to do to register properly?

    Additional Information:
    MUJR-BISM-KRDN-KKER
    056971

    Additional Information:
    0561234

    Additional Information:
    MURL-QPQU-EGBJ-FNMB

    Additional Information:
    MUCE-LFMQ-WBCW-MLHO

    Additional Information:


    Additional Information:
    LUTA-ADVJ-FXTW-FBCE

    Additional Information:
    LUTA-ADVJ-FXTW-FBCE

    Additional Information:
    looking for registration key for MUUK-IBTW-ECTL-CJWD

    Additional Information:
    MUXO-PIYY-KNHD-RKLY

    Additional Information:
    MUUE-YYCR-FCIC-VATK

    Additional Information:
    MUUE-YYCR-FCIC-VATK

    Additional Information:


    Additional Information:
    MUEY-YLJU-OBRR-LJBV

    Additional Information:
    MUSP-JFDV-EKGQ-OVLW

    Additional Information:
    MUSP-JFDV-EKGQ-OVLW

    Additional Information:


    Additional Information:


    Additional Information:
    MULY-XRYF-BBDN-FBWP

    Additional Information:


    Additional Information:


    Additional Information:
    how to generate activation code richauto a11

    Additional Information:
    MUJC-LNIL-EOHS-YKNQ

    Additional Information:
    sdfd

    Additional Information:
    m l

    Additional Information:
    MUXC-RWKB-PKAL-HGNN

    Click the link to add information to this solution:
    THEY ARE ASKING FOR THE ACTIVATION CODE AND SERIAL NUMBER USB BOARD. HOW CAN GET THAT INFORMATION?

  • [575] Is there a way to use an X,Y plate that will only be responsible for corner finding?

    Yes, you can use a corner plate very easily. You will want to make a corner plate that has three independent plates that do not conduct with each other. Each of these plates will be connected to a different input (i.e. IN1 for X, IN2 for Y and IN3 for Z). The end mill or tool that is inserted into the spindle will connect to V- of the 24V power supply, or the DCM on the controller, which is connected to the 24V V-. Then, you can use the ref all home button on the program run screen of Mach3.

    Click the link to add information to this solution:
    [575] Is there a way to use an X,Y plate that will only be responsible for corner finding?

  • I AM TAKING THE FINAL YEAR PROJECT IN BASE STATIONS AND AIR INTERFACE. WOULD LIKE TO HAVE SOME INFORMATION.

    The Federal Communications Commission (FCC) is the primary federal agency responsible for safety aspects of modern-day wireless telecommunications systems. The FCC's Internet address is shown below. Recently FCC published an excellent report, cited below, to assist citizens and local governments dealing with siting of telecommuncations towers. This report contains charts and figures describing the characteristics and performance of telecommunications antennas. The report also contains practical guidance on application of provisions of the Telecommunications Act of 1996, which is the governing legislation regarding safety and siting of wireless telelcommunications facilities. Web page: RF Safety Program Page. Report title: "A Local Government Official's Guide to Transmitting Antenna RF Emission Safety: Rules, Procedures, and Practical Guidance." The Local and State Government Advisory Committee (LSGAC) and the FCC have developed this guide to aid local governmental officials and citizens in understanding safety issues related to radiofrequency emissions from telecommunications towers. Gary Zeman, Sc.D., CHP Lawrence Berkeley National Laboratory

    Click the link to add information to this solution:
    I AM TAKING THE FINAL YEAR PROJECT IN BASE STATIONS AND AIR INTERFACE. WOULD LIKE TO HAVE SOME INFORMATION.

  • [575] I cant get a 5v signal on any of the Outputs on the board. what Port# and Pin #s should I be using on Mach3?

    The Mach3 USB controller does not provide 5V output signals. The Inputs, Outputs, and PWM Spindle Speed terminals are separated from the 5V side of the board. The output terminals use the 24V portion of the controller and you will need a 24V power supply to make these outputs work.

    Please watch the video below to completely understand how the outputs of this controller work. Make sure that you are using the RNRmotion.dll plugin and that the port for each of the outputs is set to port 3.

    Click the link to add information to this solution:
    [575] I cant get a 5v signal on any of the Outputs on the board. what Port# and Pin #s should I be using on Mach3?

  • THERE ANY STANDARD FOR A DISTANCE BETWEEN CELLULAR BASE STATION AND RESIDENTIAL AREA?

    The two main constraints on siting cellular base stations near residential areas are government exposure limits and local zoning ordinances. Various governments have limits for human exposure to radiofrequency (RF) energy that must be complied with in the siting of cellular base stations and other transmitters. In the United States, the relevant limits are those of the Federal Communications Commission (FCC). Cellular base stations use low-powered transmitters, and RF signal levels are invariably below FCC limits at any distance more than a few feet from the antennas. Thus it is entirely feasible to locate cellular base stations on rooftops of apartment buildings and to locate communications towers within residential areas and indeed these are both common practices. Local zoning ordinances are a different story. Local governments commonly restrict the location of communications towers through zoning ordinances, and they may have provisions that restrict cellular base stations in residential districts. Local attorneys or government officials should be consulted for advice about local requirements, which vary greatly among jurisdictions. Kenneth R. Foster Professor, Department of Bioengineering University of Pennsylvania

    Click the link to add information to this solution:
    THERE ANY STANDARD FOR A DISTANCE BETWEEN CELLULAR BASE STATION AND RESIDENTIAL AREA?

  • IS THERE A WAY TO GET RID OF THE PARALLEL CABLE AND SOMEHOW USE USB ?

    If you select the Settings Page and select or tick Auto Limit Override - this will allow you to back off the switch.

    Additional Information:
    limit and home switch

    Click the link to add information to this solution:
    IS THERE A WAY TO GET RID OF THE PARALLEL CABLE AND SOMEHOW USE USB ?

  • [575] Why is a second PSU necessary for the limit switch and e-stop ?

    Because the USB board is powered by USB (+5VDC) from your PC. Your inputs (eg. limit switches) require up to +36VDC to operate properly.

    Click the link to add information to this solution:
    [575] Why is a second PSU necessary for the limit switch and e-stop ?

  • [575] Is there a special .tap g code file I should use with this mach3 controller I’m using aspire as cad

    The post-processor that should be used in Aspire, Vectric V-Carve, Cut 2D, and other CAM programs in their suite should use Mach 2/3 Arcs (inch) or Mach 2/3 Arcs (mm).

    Click the link to add information to this solution:
    [575] Is there a special .tap g code file I should use with this mach3 controller I’m using aspire as cad

  • Are there any videos detailing wiring of limit switches and stop button?

    This video may serve helpful on the homing and limit switches:
    https://www.buildyourcnc.com/PrimeronHomingandLimitSwitches.aspx

    I don't go into great detail on the wiring, however. If after you watch that video and you still need a video, please let me know and I will make a video on the wiring of limit switches and the E-stop button.

    Click the link to add information to this solution:
    Are there any videos detailing wiring of limit switches and stop button?

  • I NEED HELP IN GATHERING PUBLISHED INFORMATION ABOUT THE RISKS POSED BY CELL TOWERS PLACED ON SCHOOL GROUNDS. THERE WHICH WOULD ENABLE ME TO GATHER/CALCULATE OR MEASURE RADIATION SPECIFIC SITE?

    The best single reference is the Federal Communications Commission (FCC) Website. Look for:
    Bulletin 56, "Questions and Answers about Biological Effects and Potential Hazards of Radiofrequency Electromagnetic Fields,"

    Bulletin 65, "Evaluating Compliance With FCC Guidelines for Human Exposure to Radiofrequency Electromagnetic Fields,"

    "A Local Government Official's Guide to Transmitting Antenna RF Emission Safety: Rules, Procedures, and Practical Guidance."
    An excellent technical paper with field measurements of cell-tower emissions was published by R.C. Petersen and P.A. Testagrossa in the journal Bioelectromagnetics, volume 13, page 527ff, 1992. If you need onsite technical support and services there are various consultants available, such as Richard Tell Associates, Inc. Gary Zeman, ScD, CHP Lawrence Berkeley National Laboratory

    Click the link to add information to this solution:
    I NEED HELP IN GATHERING PUBLISHED INFORMATION ABOUT THE RISKS POSED BY CELL TOWERS PLACED ON SCHOOL GROUNDS. THERE WHICH WOULD ENABLE ME TO GATHER/CALCULATE OR MEASURE RADIATION SPECIFIC SITE?

  • What would be your recommendation for "power supply 2 (24vdc)" connecting to USB motion card? Are there any videos explaining it's connection to the relay coil? (not quite sure what relay coil is)

    A 24V connection to the USB motion card is only needed if you are using limit switches (inputs), powering the spindle/VFD speed and direction, and for the outputs, for powering other devices (mist, coolant, etc.).

    If you are using a VFD (Variable Frequency Drive, also called Inverter) for a spindle, they typically have a 24V out terminal that can be used with our USB motion card. If you are not using a spindle/VFD (we highly recommend one), then you will need to purchase a 24v power supply to power that side of the board.

    The outputs mentioned above are to connect to external devices and will require a relay (a mechanical switch that is controlled by a digital signal). This mechanical switch can turn on a device like coolant and mist, or even a router, if you are using one. A relay is required to turn on these devices because the devices are typically higher voltage, like mains (110v or 220v). So, a relay can turn on or off a high voltage device with a lower voltage (24v) signal.

    Click the link to add information to this solution:
    What would be your recommendation for "power supply 2 (24vdc)" connecting to USB motion card? Are there any videos explaining it's connection to the relay coil? (not quite sure what relay coil is)

  • I HAVE FOLLOWED YOUR YOUTUBE VIDEO ON SETTING UP THE POKEYS 57CNC BOARD BUT WHEN OPEN MACH 4 GET A ERROR MESSAGE CONNECTION IS TO SLOW

    I have not come across this problem, but there may be USB, or firmware issues that you are experiencing. I would recommend going on the polabs website and using their support center (https://support.poscope.com/)and posing that question to them. Also, have you tried the ethernet port as an alternative to see if that helps?

    Here is the response from an LLM:

    Check USB Cable and Port: Start with the basics. Sometimes this error is due to a poor USB connection. Ensure you're using a high-quality, shielded USB cable and that it's plugged into a USB port directly on your computer, not through a hub. If possible, try a different USB port or a different cable to rule out any issues there.

    Update Firmware and Software: Ensure that both your PoKeys57CNC firmware and the Mach4 software are up to date. Firmware updates for your PoKeys board might include optimizations or fixes that address connectivity issues.

    USB Polling Rate: This error can also arise from the USB polling rate setting in the PoKeys configuration software. It might be set too high for your system's ability to handle it. Try lowering the polling rate and see if that resolves the error.

    Computer Performance: Check your computer’s performance. If it’s running several heavy applications simultaneously, it might not be able to process signals from the PoKeys board fast enough. Try closing unnecessary applications or consider using a dedicated machine if your current setup is too taxed.

    Mach 4 and PoKeys Plugin Configuration: Dive into the Mach 4 plugin configuration for PoKeys. Ensure that all settings are correctly configured as per the manual. Incorrect settings might lead to communication bottlenecks.

    Connection Quality and Interference: Consider any potential interference sources near your CNC setup or computer. Electromagnetic interference from large motors, other electronics, or long cable runs can affect communication quality. Try rearranging your setup to minimize interference.

    Consult Documentation and Support: If the issue persists, consult the detailed documentation provided by PoKeys or reach out to their customer support. They can offer more specific advice based on the latest product updates or known issues.

    Click the link to add information to this solution:
    I HAVE FOLLOWED YOUR YOUTUBE VIDEO ON SETTING UP THE POKEYS 57CNC BOARD BUT WHEN OPEN MACH 4 GET A ERROR MESSAGE CONNECTION IS TO SLOW

  • I WOULD LIKE TO KNOW IF THERE IS A STORE OR SHOP WHERE CAN SEE THE PRODUCT AND BUY IT?

    If you are located near Houston, Texas area you can stop by our shop. If you are not near us, you can check in our forums, and see if you can find someone in your area that has one of our machines, and would be willing to let you come see it in action.

    Click the link to add information to this solution:
    I WOULD LIKE TO KNOW IF THERE IS A STORE OR SHOP WHERE CAN SEE THE PRODUCT AND BUY IT?

  • Is there a warranty on the NEMA 34 651 Oz-in stepper motors you sell?

    Yes, we honor a one year warranty on the NEMA 34 651 oz-in stepper motor.

    Click the link to add information to this solution:
    Is there a warranty on the NEMA 34 651 Oz-in stepper motors you sell?

Get Help with:
This Product
Orders
Tech Support
Sales
This Product
Order Query
Tech Support
Sales
Not logged in. Log In Register
Track Order(s)
View Order(s)
I Want to Schecule a One-On-One Paid Tech Support Session
Book an Appointment Pertaining to a BuildYourCNC Product (Free)
Ask a Quesion Below (Free):
Book an Appointment Pertaining Other Equipment ($60/half hour)
Book an Immedite Appointment Pertaining Other Equipment ($120/half hour)
Ask a Quesion Below (Free):
Waiting for response... I may not answer immediately, but I was notified on my cellular phone so my response is forthcoming. If I don't respond immediately, you can always go to the [My Account] page to see all of our chats at any time.