Question #: 14383

Question: I have a GMT 2.2kw water cooled spindle that sounds like the bearings are going out and want to know if your spindle (https://buildyourcnc.com/Item/spindle-inverter-2!2kw-spindle-novfd) is comparable for a swap. The drive is a Delta VFD-M 220v.

Current Solution

Our spindle should work fine with your Delta VFD-M 220v. Spindles that match a VFD are specific to the coil windings. The bearings, shaft and other mechanical components that make up the spindle may be different, but that should not matter.

Respond:

Other Possible Solutions to this Question

  • I am making my own CNC setup using all the electronics from your website and I have many questions. Please advise how to have my computer recognize the USB connection from my breakout board also I would like to use a water cooled spindle but I need to know the parts required for a 4x10 bed area used for woods and plastics

    You will need PlanetCNC software for the USB breakout board and when plugging in the USB the computer should automatically recognize the board, however you can go into device manager to see if the USB terminal is working correctly.
    The parallel breakout board; the USB is not a connection terminal rather than a power source, and the parallel port will be the communication terminal.
    The items you will need for a water cooled spindle would be: water pump, silicon tubing(length desired by customer), a extension cord(from a hardware store(orange))(1 same gauge wire/length as extension cord).

    Click the link to add information to this solution:
    I am making my own CNC setup using all the electronics from your website and I have many questions. Please advise how to have my computer recognize the USB connection from my breakout board also I would like to use a water cooled spindle but I need to know the parts required for a 4x10 bed area used for woods and plastics

  • I am looking at purchasing your 2.2 kw water cooled spindle. I'm assuming it comes with the VFD. I have a rotary phase converter in my shop. Are these spindles 3 phase? And if so, can I bypass use of the VFD and control the spindle speed by the CAM software instead? Or is the VFD an absolute necessity to use on the spindle?

    Identify the Control Signals: First, determine which control signals from the DB25 interface card are used for spindle speed control. Typically, these are PWM (Pulse Width Modulation) signals or analog voltage signals.

    VFD Configuration: Your VFD should be configured to accept the type of control signal your DB25 card provides. This involves setting parameters in the VFD that correspond to the type of input signal it will receive for speed control.

    Wiring: Connect the appropriate output pins from the DB25 card to the input terminals on the VFD. This usually involves connecting the PWM or analog output to the corresponding input on the VFD. Make sure to consult the manuals for both your VFD and interface card for specific wiring details.

    UCCNC Settings: Configure UCCNC to output the correct type of signal (PWM or analog) that matches your VFD's configuration. This is done through the software's spindle setup section.

    Test and Adjust: Run some tests to ensure that the spindle speed is being correctly controlled by UCCNC. You might need to tweak settings in either the VFD or UCCNC for optimal performance.

    Click the link to add information to this solution:
    I am looking at purchasing your 2.2 kw water cooled spindle. I'm assuming it comes with the VFD. I have a rotary phase converter in my shop. Are these spindles 3 phase? And if so, can I bypass use of the VFD and control the spindle speed by the CAM software instead? Or is the VFD an absolute necessity to use on the spindle?

  • What are the configuration settings for VFD for Spindle 1.5kW 110V. The search settings have a link for a 2.2kw spindle so I'm afraid they are the wrong ones and I don't want to fry the spindle. My VFD is an Huanyang HY01D511B.

    Did you get a manual for your VFD? Where did you purchase the VFD and spindle?

    Additional Information:
    I bought the VFD through Amazon with a similar spindle that you sell. The VFD came with a manual but unfortunately the spindle had all the model number and specs scratched off of it. In an attempt to set it up, I fried the spindle. I have complained to the vendor and to Amazon but have received no solution. If your spindle arrives with proper documentation I probably can set it up myself.

    Click the link to add information to this solution:
    What are the configuration settings for VFD for Spindle 1.5kW 110V. The search settings have a link for a 2.2kw spindle so I'm afraid they are the wrong ones and I don't want to fry the spindle. My VFD is an Huanyang HY01D511B.

  • With your 120v drive systems for your 2.2kw spindles, do you do something to limit the output to the spindle so that the current draw doesn't exceed the 80% limitations of a 20a circuit? I have a dedicated circuit for my router and I am considering a spindle upgrade, but I am curious how the configuration matches the math.

    Yes. The VFD (Variable Frequency Drive) has a large set of parameters that can be modified. This is typically called "programming" the VFD. The parameters can be accessed using the front control panel of the VFD.

    Since the VFD is the mechanism that control the allowable current draw from the spindle, there is a parameter that assigns the motor rated current; however, it is probably better to match the rated current of the motor and "up" the circuit breaker current instead. If the current limit is set too low, then there is a possibility that the spindle will cause a current overload error on the VFD and cause the spindle to stop.

    Click the link to add information to this solution:
    With your 120v drive systems for your 2.2kw spindles, do you do something to limit the output to the spindle so that the current draw doesn't exceed the 80% limitations of a 20a circuit? I have a dedicated circuit for my router and I am considering a spindle upgrade, but I am curious how the configuration matches the math.

  • Good morning, I would like to know if the strength of the 2.2kw spindle is weaker when using the 110V version of the VFD. Does it have the same power as the 220V version VFD?

    The 2.2kW spindle will have the same amount of torque and strength using either the 110V or the 220V inverter. Nothing will significantly change in either application since the 110V inverter has a small step up transformer which will increase the voltage from 110V to 220V to run the spindle efficiently.

    Additional Information:
    I'd like confirmation on this -- isn't there a cost in efficiency to having the 110v step up to 220v?

    Additional Information:
    Thank you so very much for explaining this!!! I truly appreciate your help! Tricia

    Additional Information:
    Thank you so very much for explaining this!!! I truly appreciate your help! Tricia

    Additional Information:
    Thank you so very much for explaining this!!! I truly appreciate your help! Tricia

    Additional Information:
    Thank you so very much for explaining this!!! I truly appreciate your help! Tricia

    Additional Information:
    Thank you so very much for explaining this!!! I truly appreciate your help! Tricia

    Click the link to add information to this solution:
    Good morning, I would like to know if the strength of the 2.2kw spindle is weaker when using the 110V version of the VFD. Does it have the same power as the 220V version VFD?

  • I HAVE A 2.2KW WATER COOLED SPINDLE WITH YL620-H VFD. THE VFD USES P#-## PROGRAM FORMAT. BELIEVE ALL CORRECT SETTINGS SETUP BUT WHEN TURN UNIT ON, IT SPINS AT ABOUT 200-300 RPM REGARDLESS OF WHAT FREQUENCY CHOOSE. DO YOU PARAMETERS IN THIS FORMAT FOR UNIT? THANK YOUR HELP. HUIBERT MEES

    You will need to look for the parameter that controls the run frequency. The frequency can be controlled bu the panel, external terminals, or the RS485 TX/RX terminals (UART protocol). You will want to change that parameter so it uses the panel. If you are referring to the maximum panel dial frequency is only allowing 200-300 rpm, then look for the parameters to control the frequency.

    For 200 RPM:
    Hz = 200/60 = 3.33 Hz

    For 300 RPM:
    Hz = 300/60 = 5 Hz

    Conversion to RPM:
    If you ever find yourself yearning to reverse-engineer the process, the formula is as follows:

    RPM = Hz × 60

    Look for values that match somewhere between 3 and 5 in your frequency parameters and replace them with 400 to give you 24,000 RPM max.

    Click the link to add information to this solution:
    I HAVE A 2.2KW WATER COOLED SPINDLE WITH YL620-H VFD. THE VFD USES P#-## PROGRAM FORMAT. BELIEVE ALL CORRECT SETTINGS SETUP BUT WHEN TURN UNIT ON, IT SPINS AT ABOUT 200-300 RPM REGARDLESS OF WHAT FREQUENCY CHOOSE. DO YOU PARAMETERS IN THIS FORMAT FOR UNIT? THANK YOUR HELP. HUIBERT MEES

  • I have wired up my 110v VFD and my 2.2Kw spindle and I get an E.Lu.5 code. My wiring is correct and the parameters are set to those for the VFD according to your website I found in a previously answered question from someone here. Any help would be greatly appreciated, thank you!!

    The E.Lu.5 Error code on your VFD is related to Low Voltage.

    The recommended action is:
    - 1. Check whether the input voltage is normal. (the voltage from the wall/breaker to the VFD)
    - 2. Check whether there is a sudden change in load.
    - 3. Check whether there is any phase missing.

    Unfortunately, these three recommended actions will probable require an electrician to test the line going into the VFD.

    Additional Information:

    Click the link to add information to this solution:
    I have wired up my 110v VFD and my 2.2Kw spindle and I get an E.Lu.5 code. My wiring is correct and the parameters are set to those for the VFD according to your website I found in a previously answered question from someone here. Any help would be greatly appreciated, thank you!!

  • HI, I HAVE INTENTION OF PURCHASING YOUR 1/2 INCH PRECISION LEAD SCREW SET TO BUILD MY CNC MACHINE, COULD THE SCHEMATIC DIMENSION ANTI-BACKLASH NUT, BEARING FOR AND SHIM? ALSO IS 2.2KW SPINDLE ABLE MILL ALUMINUM WHAT ACCURACY?

    BYCNC response:

    Milling aluminum is no problem with our machines.

    Here is a video we recently did with our 4'x8' machine. The aluminum piece is about 1/4" thick: https://buildyourcnc.com/tutorials/tutorial-greenbull-aluminum-cutting

    The accuracy you will see from our our 2.2kW spindle is entirely dependent on the precision of your build, so it's not possible to say what level of accuracy you can achieve without an examination of the complete system. However, our spindles have a runout of less than .0001 in, which includes the collets that we sell. If you use a collet from another manufacturer, we cannot guarantee this TIR (Total Indicated Runout) dimension.

    For the dimension drawing of the anti-backlash nut, please contact us directly by phone or email to techsupport@buildyourcnc.com

    User response:
    I have emailed waiting for your reply.

    User response:
    Hi, I am still waiting for your email reply.

    BYCNC response:
    Your email has been sent.

    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    HI, I HAVE INTENTION OF PURCHASING YOUR 1/2 INCH PRECISION LEAD SCREW SET TO BUILD MY CNC MACHINE, COULD THE SCHEMATIC DIMENSION ANTI-BACKLASH NUT, BEARING FOR AND SHIM? ALSO IS 2.2KW SPINDLE ABLE MILL ALUMINUM WHAT ACCURACY?

  • HI, I HAVE INTENTION OF PURCHASING YOUR 1/2 INCH PRECISION LEAD SCREW SET TO BUILD MY CNC MACHINE, COULD THE SCHEMATIC DIMENSION ANTI-BACKLASH NUT, BEARING FOR AND SHIM? ALSO IS 2.2KW SPINDLE ABLE MILL ALUMINUM WHAT ACCURACY?

    BYCNC response:

    Milling aluminum is no problem with our machines.

    Here is a video we recently did with our 4'x8' machine. The aluminum piece is about 1/4" thick: https://buildyourcnc.com/tutorials/tutorial-greenbull-aluminum-cutting

    The accuracy you will see from our our 2.2kW spindle is entirely dependent on the precision of your build, so it's not possible to say what level of accuracy you can achieve without an examination of the complete system. However, our spindles have a runout of less than .0001 in, which includes the collets that we sell. If you use a collet from another manufacturer, we cannot guarantee this TIR (Total Indicated Runout) dimension.

    For the dimension drawing of the anti-backlash nut, please contact us directly by phone or email to techsupport@buildyourcnc.com

    User response:
    I have emailed waiting for your reply.

    User response:
    Hi, I am still waiting for your email reply.

    BYCNC response:
    Your email has been sent.

    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    HI, I HAVE INTENTION OF PURCHASING YOUR 1/2 INCH PRECISION LEAD SCREW SET TO BUILD MY CNC MACHINE, COULD THE SCHEMATIC DIMENSION ANTI-BACKLASH NUT, BEARING FOR AND SHIM? ALSO IS 2.2KW SPINDLE ABLE MILL ALUMINUM WHAT ACCURACY?

  • I've buffered a PWM signal to a 0-10V analog signal and I would like to use that signal to run your 110V 2.2kW spindle and VFD. Could you please detail the correct wiring and VFD settings to get that working?

    This will depend on the VFD you have to identify the correct terminal. The terminal on the VFD will be labeled AI1 typically (Analog Input #1). You will also need to make sure to complete the PWM circuit using the GND terminal on the VFD.

    Additional Information:
    I have wired my 0-10V signal to the AI1 and GND terminals as suggested. I have also set the PD-01 and PD-02 settings to 1. Still nothing. Is there something else that I am missing?

    Additional Information:
    Thanks for the information. Can you let me know the model of the VFD that you have?

    Additional Information:
    VFD Model # YL600-2S-2K20

    Additional Information:
    Thanks. I will check our resources and documentation to see if there is another programming setting that needs to be changed.

    Additional Information:
    Does your VFD have a VI terminal?

    Additional Information:
    No, it does not. The terminals for this VFD are as follows (seperated by dashes "-").

    10V-AI1-AO2-PLC-DI5-DI3-DI1-COM
    AI2-GND-AO1-DI6-DI4-DI2-FM-24V

    Additional Information:
    Do you have a PD070 parameter?

    PD070 is the main Analog Input parameter.

    The options for that parameter is:
    0: 0-10V
    1: 0-5V
    2: 0-20mA
    3: 4-20mA
    4: 0-10V (4-20mA Stacked)
    5: XIA
    6: (VI+XIA)/2
    7: (3VA+XIA)/4
    8: (XIA_XIB)/2
    9: Max (XIA, XIB)
    10: Min (XIA, XIB)


    Additional Information:
    There is a PD-00 thru PD-09. PD-07 is currently set to 0.

    Additional Information:
    It appears that the manual I’m using “Titled YL600” is not the same as your unit. I will check our manuals and find the one that has only PD-00 to PD-09.

    Additional Information:
    For that VFD, the parameters are P0. The 0 may look like a D on the display.

    The parameters that need to be changed for the AI1 to work (Brackets [] around the correct selection):

    P0-01: First Motor Control Mode
    - 0: Sensorless Vector Control
    - 1: Flux Vector Control (FVC)
    - [2]: V/F Control

    P0-02: Options of Command Source
    - 0: Operation Panel Command Channel (LED will be off)
    - [1]: Terminal Command Channel (LED will be on)
    - 2: Communication Command Channel (LED will flicker)

    P0-03: Options of Principle Frequency Source X
    - 0: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, no power-down memory)
    - 1: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, with power-down memory)
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID (Proportional Integral Derivative Control)
    - 9: Communication Given

    P0-11: Upper Limit Frequency Source
    - 0: P0-12 (Make sure the P0-12 parameter has the correct max frequency if used)
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given

    P0-27: Command Source Bundle with Frequency Sources
    Single Digit: Options of Operation Panel Command Bundle with Frequency Sources
    - 0: No Bundling
    - 1: Digital Setting Frequency
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID
    - 9: Communication Given
    Double Digit: Options of Terminal Command Bundle with Frequency Sources
    Hundred Place: Options of Communication Command Bundle with Frequency Sources
    Kilobit: Options of Automatic Operation Bundle with Frequency Sources

    P2-09: Upper Limit Source of Lower Torque Under Speed Control Mode
    - 0: Function Code P2-10 Setting
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given
    - 6: MIN (Al1, Al2)
    - 7: MAX (Al1, Al2)
    - Maximum range for options 1-7, accords with P2-10

    If you elect to use a different AI#, then configure the parameters (P0-03, P0-11, P0-27 and P2-09) accordingly.

    Click the link to add information to this solution:
    I've buffered a PWM signal to a 0-10V analog signal and I would like to use that signal to run your 110V 2.2kW spindle and VFD. Could you please detail the correct wiring and VFD settings to get that working?

  • I wpold like to know how to hook up my water pump (12vdc 9 amp) to turn it on and off using Mach 3. I have your Blue Brew break-out board Rev. 2.8 dated 8-12. Explain how the three relay connections work for this application? Thanks.

    Since the pump will use a standard 12v power supply, you will have two wires. One of those wires will be connected from the power supply to the pump. The other wire will be connected to the power supply and the pump, but cut that wire and connect one side of it in the P terminal and the other end in the S or the O terminal depending on if you need the connection as NO (Normally Open) or NC (Normally Closed).

    Step number 9 in the instruction will have the relay connection information:
    https://www.buildyourcnc.com/item/electronicsAndMotors-parallel-breakout-relay

    Click the link to add information to this solution:
    I wpold like to know how to hook up my water pump (12vdc 9 amp) to turn it on and off using Mach 3. I have your Blue Brew break-out board Rev. 2.8 dated 8-12. Explain how the three relay connections work for this application? Thanks.

  • I am building your "Green Bull' 6 foot wide kit and I am at the stage of attaching the motor and drive chain. I would like to know if you have an modification kit available to put the 1/2" ACME screw on the Y-axis?

    Currently we do not have that modification kit, our set up is fixed for our greenBull only modification kit we have for this model is the long z-axis kit(Designed for Foam cutting).

    Click the link to add information to this solution:
    I am building your "Green Bull' 6 foot wide kit and I am at the stage of attaching the motor and drive chain. I would like to know if you have an modification kit available to put the 1/2" ACME screw on the Y-axis?

  • I have one of your smaller stepper motors running my X AXIS bridge crane and if it is moved to fast the stepper motor sounds like it is skipping steps will the 651oz stepper motor require a different power supply and controler?

    Yes, the 651 oz/in motor requires a driver that is compatible to the motors (the motor will draw 6 amps max and the driver paired with this motor will be able to allow for a 6 amp draw). I would also recommend a 36 volt power supply for better high velocity performance.

    Click the link to add information to this solution:
    I have one of your smaller stepper motors running my X AXIS bridge crane and if it is moved to fast the stepper motor sounds like it is skipping steps will the 651oz stepper motor require a different power supply and controler?

  • I wired my vfd (2.2kw version) and tried test running the spindle. I configured to your specs on this website, only issue is we got an error code. Err 02, do you know what this is? OR have a list of error codes? Thank you

    Can you provide the model number of your VFD?

    Yes, I have the "YL600 - 2S - 2K20"

    It just came with a small booklet that is all in Chinese...

    Click the link to add information to this solution:
    I wired my vfd (2.2kw version) and tried test running the spindle. I configured to your specs on this website, only issue is we got an error code. Err 02, do you know what this is? OR have a list of error codes? Thank you

  • I would like to know what the lowest rpm that can be acheived with the 2.2kw spindle and inverter and still have enough torque to drill

    According to the supplier of the 2.2 kW spindle, the safest operating speed for the spindle is 6000 RPM. The supplier also stated that theoretically, the spindle can operate from 0 to 24,000 RPM. I am continuing a dialog with the supplier to delve deeper into understanding the configurations and ramifications of such configurations for operations outside of the safe boundaries into the "theoretical" ranges.

    Additional Information:
    20

    Click the link to add information to this solution:
    I would like to know what the lowest rpm that can be acheived with the 2.2kw spindle and inverter and still have enough torque to drill

  • Hi, I'm interested in the 1.5 kW (kilowatt) Water Cooled Spindle with Inverter (VFD), I would like to know about the run out of this spindle?

    Our spindles have a runout of less than .0001 in, which includes that collets that we sell. If you use a collet from another manufacturer, we cannot guarantee this TIR (Total Indicated Runout) dimension.

    Additional Information:



    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    Hi, I'm interested in the 1.5 kW (kilowatt) Water Cooled Spindle with Inverter (VFD), I would like to know about the run out of this spindle?

  • I HAVE ONE OF YOUR SMALLER STEPPER MOTORS RUNNING MY X AXIS BRIDGE CRANE AND IF IT IS MOVED TO FAST THE MOTOR SOUNDS LIKE SKIPPING STEPS WILL 651OZ REQUIRE A DIFFERENT POWER SUPPLY CONTROLER?

    Yes, the 651 oz/in motor requires a driver that is compatible to the motors (the motor will draw 6 amps max and the driver paired with this motor will be able to allow for a 6 amp draw). I would also recommend a 36 volt power supply for better high velocity performance.

    Click the link to add information to this solution:
    I HAVE ONE OF YOUR SMALLER STEPPER MOTORS RUNNING MY X AXIS BRIDGE CRANE AND IF IT IS MOVED TO FAST THE MOTOR SOUNDS LIKE SKIPPING STEPS WILL 651OZ REQUIRE A DIFFERENT POWER SUPPLY CONTROLER?

  • I have a 2.2kw water cooled spindle with a YL620-H VFD. The VFD uses the P#-## program format. I believe I have all the correct settings setup but when I turn the unit on, it spins at about 200-300 RPM regardless of what frequency I choose. Do you have the correct program parameters in this format for this unit? Thank you for your help. Huibert Mees

    You will need to look for the parameter that controls the run frequency. The frequency can be controlled bu the panel, external terminals, or the RS485 TX/RX terminals (UART protocol). You will want to change that parameter so it uses the panel. If you are referring to the maximum panel dial frequency is only allowing 200-300 rpm, then look for the parameters to control the frequency.

    For 200 RPM:
    Hz = 200/60 = 3.33 Hz

    For 300 RPM:
    Hz = 300/60 = 5 Hz

    Conversion to RPM:
    If you ever find yourself yearning to reverse-engineer the process, the formula is as follows:

    RPM = Hz × 60

    Look for values that match somewhere between 3 and 5 in your frequency parameters and replace them with 400 to give you 24,000 RPM max.

    Click the link to add information to this solution:
    I have a 2.2kw water cooled spindle with a YL620-H VFD. The VFD uses the P#-## program format. I believe I have all the correct settings setup but when I turn the unit on, it spins at about 200-300 RPM regardless of what frequency I choose. Do you have the correct program parameters in this format for this unit? Thank you for your help. Huibert Mees

  • I was wondering what you recommend to use to cool your spindle when continuously exposed to freezing temperature. Can I use winter windshield cleaner (cheap) or do I have to use antifreeze engine coolant or something else? water just sounds like a really bad idea. I live in Canada Eh!

    Using Anti-Freeze in the cooling system with either our spindle or our laser tubes will not have any problems and we recommend using a small amount in locations where temperature is freezing or below.
    Although we do not recommend using an entire gallon of anti-freeze rather just a small quantity with tap water will be sufficient.

    Additional Information:


    Additional Information:
    All last winter, the temperature was below freezing and sometimes below zero. I used 100% antifreeze for the spindle coolant. Worked great !! All the spindle needs is any type of coolant flowing through it to take the heat away. I use three gallons of antifreeze in a tub with a fish-tank pump to push the antifreeze through. 100% antifreeze works great in cold or hot winter.

    Additional Information:
    Excellent tip. Thank you for this correction. So it is OK to use antifreeze solely as a cooling method.

    Click the link to add information to this solution:
    I was wondering what you recommend to use to cool your spindle when continuously exposed to freezing temperature. Can I use winter windshield cleaner (cheap) or do I have to use antifreeze engine coolant or something else? water just sounds like a really bad idea. I live in Canada Eh!

Get Help with:
This Product
Orders
Tech Support
Sales
This Product
Order Query
Tech Support
Sales
Not logged in. Log In Register
Track Order(s)
View Order(s)
I Want to Schecule a One-On-One Paid Tech Support Session
Book an Appointment Pertaining to a BuildYourCNC Product (Free)
Ask a Quesion Below (Free):
Book an Appointment Pertaining Other Equipment ($60/half hour)
Book an Immedite Appointment Pertaining Other Equipment ($120/half hour)
Ask a Quesion Below (Free):
Waiting for response... I may not answer immediately, but I was notified on my cellular phone so my response is forthcoming. If I don't respond immediately, you can always go to the [My Account] page to see all of our chats at any time.