[ Log In ]
[ Register ]

Question #: 15397

Question: i need wiring from vfd to spindle, prefer with vfd connector? about 15 feet. do you have or suggest where to get some.

Current Solution

You can find wiring diagrams and illustrations for the spindle on this page: https://buildyourcnc.com/item/spindle-inverter-2!2kw-spindle-novfd

This information pertains to the 2.2 kW spindle; however, the wiring is the same for the other spindles as well.

Respond:

Other Possible Solutions to this Question

  • i need wiring from vfd to spindle, prefer with vfd connector? about 15 feet. do you have or suggest where to get some.

    You can find wiring diagrams and illustrations for the spindle on this page: https://buildyourcnc.com/item/spindle-inverter-2!2kw-spindle-novfd

    This information pertains to the 2.2 kW spindle; however, the wiring is the same for the other spindles as well.

    Click the link to add information to this solution:
    i need wiring from vfd to spindle, prefer with vfd connector? about 15 feet. do you have or suggest where to get some.

  • I am missing the wiring information for the 1.5kw spindle, my electrician says I need documentation for the 4 prong connector into the VFD

    You can find wiring diagrams and illustrations for the spindle on this page: https://buildyourcnc.com/item/spindle-inverter-2!2kw-spindle-novfd

    This information pertains to the 2.2 kW spindle; however, the wiring is the same for the other spindles as well.

    Click the link to add information to this solution:
    I am missing the wiring information for the 1.5kw spindle, my electrician says I need documentation for the 4 prong connector into the VFD

  • Does the break out board come with the short ribbon connectors? Mine was soldered together and the new one comes with a plug. If it does not come with one where do I get one, I need the short ribbon connector to go with it.

    The Breakout Board is a single product assembly, it will not include a short ribbon cable nor connectors. You can find the parts required to build or make your specific ribbon cable in our motion electronics page or follow the links below:

    25 Conductor Flat Ribbon Cable: https://buildyourcnc.com/item/electronicsandmotors-connector-DB25-conductor-ribbon-cable

    25 pin D-Sub Male connector: https://buildyourcnc.com/item/electronicsandmotors-connector-male-dsub-DB25-ribbon

    25 pin D-Sub Female connector: https://buildyourcnc.com/item/electronicsandmotors-connector-female-dsub-DB25-ribbon

    You can also buy a complete DB-25 cable:
    Male to Female Parallel Cable: https://buildyourcnc.com/item/electronicsAndMotors-cable-wire-db25-male-female
    Male to Male Parallel Cable: https://buildyourcnc.com/item/electronicsAndMotors-cable-wire-db25-male-male

    Click the link to add information to this solution:
    Does the break out board come with the short ribbon connectors? Mine was soldered together and the new one comes with a plug. If it does not come with one where do I get one, I need the short ribbon connector to go with it.

  • purchased assembled greenbull with electronics, need wiring diagram from rs485/breakout to VFD 110 v

    It is possible to connect and configure the spindle VFD to the mach3 via an RS485 communication and protocol.

    The first thing you will need is the dynamic link library to pair with mach3 called the Huanyang VFD Mach3 PlugIn. You can find this file at the mach3 support forum here: http://www.machsupport.com/forum/index.php/topic,14182.0.html

    You will also need to download the Microsoft .net 3.5 framework and install it: https://www.microsoft.com/en-us/download/details.aspx?id=21

    Follow the pdf that comes with the library file, but here is a synopsis of what you need to do (I also added a lot more information that may be useful during this process as the manual does not cover the main connections that need to be done):

    You will need to program your VFD so that it knows how to communicate with mach3 and the computer (go into the programming mode of the VFD and change these parameters):
    - PD001 - value 2 - Enables with communication aspect of the VFD
    - PD002 - value 2 - Enables frequency control from the communcations port
    - PD163 - value 1 - VFD address
    - PD164 - value 1 - Baud rate of 9600 (speed of the communication)
    - PD165 - value 3 - 8N1 RTU - 8 bits (that's the size of the word that gets communicated), N (No parity or no error checking) and 1 (1 stop bit)

    Copy the dll file to the PlugIns folder of mach3.

    Connect the RX and TX lines to your computer. There are a couple ways you can do this, but the recommended way would be to use an FTDI USB device which converts a USB to a serial com port. The device will have Rx and Tx connectors to connect to the VFD terminals with the same labels. This method is recommended since serial ports are not as common in computers these days.

    Next, you will need to configure mach3 to use the plugin library. Start mach3 and click on Menu -> config ->Config Plugins. Enable the new plugin by clicking on the red cross on the left column next to the plug in. Restart mach3 after doing this.

    No you need to configure mach3 to use the HuanyangVFD plugin. Go to the ports & pins configuration and select the spindle setup tab. Make sure that the Disable Spindle Relays checkbox is unchecked. We don't want mach3 to output a signal for a relay since the spindle will start up and turn off within the VFD and not from an external relay.

    Next, go to the HuanyangVFD settings by clicking on Menu -> plugin control -> HuanyangVFD. Set the parameters to the same settings you put into the VFD programming. The com port will be shown as new hardward when you plug in the USB FTDI device. A little bubble will be displayed at the bottom right where it will notify you that a new device is being installed (be patient while windows assigns a com port). Alternatively, you can use the windows device manager to see which port was set for the new USB FTDI device). You may need to restart mach3 several times until you get the correct information displayed in the PD001 and PD002 fields. When the com port is correct and the other parameters, like baud and VFD address is the same as you entered in the programming, then the PD001 and PD002 will show the number 2, otherwise, a 99 will appear which means that communication was not successful.

    You can now control the on/off and RPM of the spindle using the RS485 communication between mach3 and the VFD.

    Additional Information:
    Will this work with the brand called "best "vfd as well.

    Additional Information:
    Where Can i find vfd plug-in for yl-620a for mach3 MODBUS?

    Click the link to add information to this solution:
    purchased assembled greenbull with electronics, need wiring diagram from rs485/breakout to VFD 110 v

  • I want to purchase some items from your co. How do i go about it. I already have the buildyourcnc book and wand to begin.

    For purchasing on our website, our account log in is a safe way to keep your personal data at hand for future orders. However we do not keep any bank information in our systems, it is a single use system.

    Now dealing with the cnc book, you can view our web version of the book with a list of materials and hardware that will be needed here (https://www.buildyourcnc.com/cnckitintro.aspx).

    Adding the items to your cart in the quantity's needed, now for certain items for example, or ACME screws, and aluminum angles will require a total length needed, but the specific lengths required will have to be email here (customerservice@buildyourcnc.com) or called here (281-815-7701) with the completion of your order.

    Click the link to add information to this solution:
    I want to purchase some items from your co. How do i go about it. I already have the buildyourcnc book and wand to begin.

  • What do I need to purchase from you to get me running. I have planet cnc control board but it is difficult contacting them when I need help.

    Software specific questions for Planet-CNC will have to come from them or other sources as we are not fully equipped to troubleshoot all issues. If the issue is related to motor tuning or setup involving our electronics, then we will gladly assist you. You may contact techsupport@buildyourcnc.com with inquiries.

    Click the link to add information to this solution:
    What do I need to purchase from you to get me running. I have planet cnc control board but it is difficult contacting them when I need help.

  • Hi I have a Proxxon MF70, I want to add 3axis stepper with controller and software by USB. Can you suggest a kit for me? Thanks.

    To implement a electronics combo to run you Proxxon MF70, you will need to find the correct drive components (ACME screw, linear rail, etc) and look into any specific modifications needed to your rig.
    I would recommend the USB 3 Axis Large Motors Electronics w/ USB Interface Board.
    Since the machine is metal, our larger motors would be highly recommended.

    We have not done this conversion, through research is recommended.

    Additional Information:



    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    Hi I have a Proxxon MF70, I want to add 3axis stepper with controller and software by USB. Can you suggest a kit for me? Thanks.

  • My Question is about the 2.2kw spindle, because the thread start is so small I have a hard time centering the collet before it binds from tighting what have others done to overcome this

    Can you see any damage to the beginning of the thread on the shaft of the spindle, or any damage to the thread on the inside of the collet nut?

    Additional Information:
    There is no damage, I cannot put a tool in without removing the nut and collet when I go to tighten it, it starts to seat the collet and if I cannot hold the tool just right it is off center

    Additional Information:
    The ER collets should actually snap in to the collet nut, which eliminates that issue

    Additional Information:
    The ER collets should actually snap in to the collet nut, which eliminates that issue

    Additional Information:
    The ER collets should actually snap in to the collet nut, which eliminates that issue

    Click the link to add information to this solution:
    My Question is about the 2.2kw spindle, because the thread start is so small I have a hard time centering the collet before it binds from tighting what have others done to overcome this

  • I need wiring instructions for the breakout board you sent yesterday. It is not like the one in the videos and I don't know where to connect the 5V. No data sheet or anything.
  • I received a VFD 110v yl600-2s-2k20 p 110v with 220v instructions, also the connectors on the VFD dose not match any wiring configuration you have.

    Ok, I will check the YL600 documentation Monday 4/3 and provide the answer here.

    Additional Information:


    Additional Information:
    I also received one of these and the button labels do not even match your programming instructions as stated on your web set. Please provide updated instruction to match the model shipped with the correct button names to press in The programming process.

    Additional Information:
    7/15/17 - I have exact problem. I do not see the solution posted???

    Additional Information:
    Mine is a 2.2Kw YL-620 connected to a 1.5Kw spindle.

    Code Address Function Set Range &Function Explanation Factory Setting User Set Vendor Suggested As shipped Code Address Decimal
    P00.00 0 Main Frequency 0-120HZ(400HZ) 50.0HZ  400 60 399.6 P00.0 0
    P00.01 1 Start / stop command source 0: Operator board 0 0  0 P00.1 1
    1:From external end control Electric machinery,operation panel STOP key effective
    2:From external end son control Electric machinery,operation panel STOP key invalid
    3:from (Modbus Rs485) control Electric machinery
    4:By user application program control Electric machinery
    P00.02 2 Reserved   0   0 P00.2 2
    P00.03 3 Stopping Mode 0:Decelerating stop 0 0  1 P00.3 3
    1:Coasting stop 10
    2:DC brake stop 0.2
    P00.04 4 VF:Highest output frequency 1.0-120.0HZ(400HZ) 50.0HZ 400 60 400 P00.4 4
    P00.05 5 VF:Maximum Voltage Output Frequency 5.0-120.0HZ(400HZ) 50.0HZ 400 60 400 P00.5 5
    P00.06 6 VF:Highest output Voltage 10.0%-150.0% 100.00% 100.00% 100.00% 100 P00.6 6
    P00.07 7 VF:Middle Frequency 1.0-120.0HZ(400HZ) 3.0Hz 3.5Hz 3.0Hz 3.5 P00.7 7
    P00.08 8 VF:Middle Voltage 10.0%-100.0% 10% 20% 10% 10 P00.8 8
    P00.09 9 VF:Min Frequency 0-120.0HZ(400HZ) 0.2HZ 0.2Hz 0.2Hz 0.2 P00.9 9
    P00.10 10 VF:Min Voltage 0%-100.0% 5% 10.00% 5.00% 5 P00.10 10
    P00.11 11 Analog Input quantity 1 Regulation Multistage velocity 0%-100% 100 100 100 100 P00.11 11
    P00.12 12 VF :Curve Setting 0-4 0 0 P00.12 12
    P00.13 13 Parameter Lock 0: lnvalid 0 0 P00.13 13
    1: Valid
    10: Restore the factory setting No other function
    P00.14 14 Reserved 0 0 P00.14 14
    P00.15 15 Power on Time prohibit External end son Start-up 0:Power on time,allow External end input effective level,start-up Electric machinery 0 0 P00.15 15
    1:Power on time,Not allow
    P00.16 16 0: FWD(X5)yes,Positive run the 0 P00.16 16
    1: REV(X6) Determine direction : Open Yes
    2:X_EF=EF,X_REV(X5)_DIR=DIR,FWD(X6)=
    3: Stop ,FWD(X5) turn off Instantaneous
    4: FWD(X5) turn off Instantaneous
    5: FWD(X5) turn off Instantaneous
    6: Stop ,FWD(X5) turn off Instantaneous
    7: REV(X6)When open,FWD(X5)Start-up
    P00.17 17 Many function input X1 function Choice ####################################### ####################################### 1 1 P00.17 17
    P00.18 18 Many function input X2 function Choice 1.0HZ 1 P00.18 18
    P00.19 19 Many function input X3 function Choice 1 P00.19 19
    P00.20 20 Many function input X4 function Choice 1 P00.20 20
    P00.21 21 External Terminal rise/Slow down increment 0-120HZ(400HZ) 1.0HZ 1 P00.21 21
    P00.22 22 External Terminal rise/Slow down time interval 0.2 0.2 P00.22 22
    P00.23 23 Physics amount display Proportion constant 0-999.9% 100.00% 100 P00.23 23
    P00.24 24 After power supply, display project choice 0: Display current target frequency 0 0 P00.24 24
    1:Display Electric machinery run frequency.
    2:Display Electric machinery run current.
    3:Display input AC voltage
    4:Display mother Line voltage
    5:Display output voltage
    6:Display speed paragraph Number SP x
    7:Display inverter temperature t xx
    8:Display input signal X1-X3/output signal
    9:Display user variable
    10:Display user Count value
    11:Display temporary debugging variable
    12:Display automatic multi segment run step and time
    P00.25 25 Display project automatic Return delayed time (10/S) 0:No,Automatic return;1-6delayed 10-60S Back Return 1 1 P00.25 25
    P01.00 256 REV Rotation Select 0: Rev Run Enable 0 0 P01.0 256
    1: Rev Run Forbidden 0
    P01.01 257 Electric machinery Reversing wait for time 0 P01.1 257
    P01.02 258 Deceleration Prevention overvoltage setting(%) 130 130 P01.2 258
    P01.03 259 Accelerated Prevention overcurrent setting(%) 130 130 P01.3 259
    P01.04 260 Overcurrent Set up (%) 200 200 P01.4 260
    P01.05 261 Overload protection Set up (%) 130 130 P01.5 261
    P01.06 262 Overload protection time Set up (s) 120 120 P01.6 262
    P01.07 263 Undervoltage protection Set up (%) 80 80 P01.7 263
    P01.08 264 Overvoltage protection Set up (%) 150 150 P01.8 264
    P01.09 265 After shutdown, start DC Brake voltage Setup (%) 15 15 P01.9 265
    P01.10 266 After shutdown, End DC Brake voltage Setup (%) 0 0 P01.10 266
    P01.11 267 After shutdown, DC Braking Time Set up 2 2 P01.11 267
    P01.12 268 After shutdown, DC Braking Initial Frequency Set up 0.6 0.6 P01.12 268
    P01.13 269 Before start , input DC brake voltage set up (%) 20 20 P01.13 269
    P01.14 270 Before start , End DC Brake voltage Set up (%) 15 15 P01.14 270
    P01.15 271 Before start , DC Braking Time Set up 3 3 P01.15 271
    P01.16 272 Direct start Initial frequency (Improve starting torque ) 100 100 P01.16 272
    P01.17 273 Direct start Initial frequency Hold time 0 0 P01.17 273
    P01.18 274 power failure frequency decline 80 80 P01.18 274
    P01.19 275 The power down frequency decline rate 5 5 P01.19 275
    P01.20 276 Restart No load time 10 10 P01.20 276
    P01.21 277 Restart voltage rise time 200 200 P01.21 277
    P02.00 512 When speed up torque will increased   100  100 100 60 P02.0 512
    P02.01 513 Deceleration time - Torque Boost   100  100 100 60 P02.1 513
    P02.02 514 Accelerate curve Choice 0  0 P02.2 514
    P02.03 515 Deceleration curve Choice 0  0 P02.3 515
    P02.04 516 Avoid the f requency 1 20 400 P02.4 516
    P02.05 517 Avoid the f requency 2 30 30 P02.5 517
    P02.06 518 Avoid the f requency 3   40 40 P02.6 518
    P02.07 519 Avoid the f requency Width   0 0 P02.7 519
    P02.08 520 Window frequency 1 45 45 P02.8 520
    P02.09 521 Window frequency 2 50 50 P02.9 521
    P02.10 522 ? 400 P02.10 522
    P03.00 768 RS485 Communication Baud Rate 0: 1200Bps 5 4 P03.0 768
    1: 2400Bps
    2: 4800Bps
    3: 9600Bps
    4: 19200Bps
    5: 38400Bps
    6: 57600Bps
    P03.01 769 RS485 Communication Addresses 1-254 10 10 P03.1 769
    P03.02 770 0: 8 bit data, 1 stop bits, odd parity 2 2 P03.2 770
    1: 8 bit data, 1 stop bits, parity check
    2: 8 bit data, 1 stop bit, no parity
    3: 8 bit data, 2 stop bits, odd parity
    4: 8 bit data, 2 stop bits, parity check
    5: 8 bit data, 2 stop bit, no parity
    P03.03 771 Communication error handling 0 P03.3 771
    P03.04 772 Communication error tolerance time 20 P03.4 772
    P03.05 773 4-20mA Break detection time 0 P03.5 773
    P03.06 774 Panel potentiometer,Lower limit of AD norm 3 P03.6 774
    P03.07 775 Panel potentiometer,Upper limit of AD specification 1020 1015 1015 P03.7 775
    P03.08 776 Panel potentiometer, frequency given of lower limit 0.0HZ 0 0 P03.8 776
    P03.09 777 Panel potentiometer, frequency given of Upper limit 0-120HZ(400HZ) 60.0HZ 400  60Hz 400 P03.9 777
    P03.10 778 Analog lnput 1 AD lower limit 0-1023 3.0Hz  60Hz 3 P03.10 778
    P03.11 779 Analog lnput 1 AD Upper limit 0-1023 1020 1010 1010 P03.11 779
    P03.12 780 Analog lnput 1 frequency given lower limit 0.0HZ 0 P03.12 780
    P03.13 781 Analog lnput 1 frequency given Upper limit 60.0HZ 400 400 P03.13 781
    P03.14 782 Analog lnput 2 AD lower limit 3.0Hz 3 P03.14 782
    P03.15 783 Analog lnput 2 AD Upper limit 1020 1010 1010 P03.15 783
    P03.16 784 Analog lnput 2 frequency given lower limit 0.0HZ 0 P03.16 784
    P03.17 785 Analog lnput 2 frequency given Upper limit 60.0HZ 60 P03.17 785
    P03.18 786 Analog output correlation 0 0 P03.18 786


    P03.19 787 Analog output gain setting 100 100 P03.19 787
    P04.00 1024 Mo analog multiplier output frequency multiplier 10 10 P04.0 1024
    P04.01 1025 Mo1 Function Options 0 0 P04.1 1025
    P04.02 1026 Mo2 Function Options 1 1 P04.2 1026
    P04.03 1027 Multi-function Relay 1 Function selection 0:fault Yes Electric , otherwise power failure 0 2 2 2 P04.3 1027
    P04.04 1028 Multi-function Relay 2 Function selection 1:Running Yes Electric ,otherwise power failure 3 3.0Hz 3 P04.4 1028
    2: Reserved
    3: Arbitrary frequency arrival Time, have Electric,Related to P02-10 settings
    4: , The power down Time,have Electric
    5:, low voltage Time, have Electric
    6:, Overvoltage Time, have Electric
    7: Overcurrent Time, have Electric
    8: Nonzero velocity Time,have Electric
    9:, DC brake Time, have Electric
    10: Over torque Time, have Electric
    11: External interrupt fault Time, have
    12: Forward Time, have Electric
    13: Reversal Time, have Electric
    14: Move Time, have Electric
    15: Accelerate Time, have Electric
    16: Deceleration Time, have Electric
    17: Constant speed Time, have Electric
    18:X1 close Time, have Electric
    19:X2 close Time, have Electric
    20:X3 close Time, have Electric
    21:X4 close Time, have Electric
    22:X5 close Time, have Electric
    23:X6 close Time, have Electric
    24: Forward and bus voltage greater than 400V Time, have Electric
    25: Reverse and bus voltage greater than 400V Time, have Electric
    P04.05 1029 Multi-function Relay 1 Action close Delayed 0-65.5 S 0 0 P04.5 1029
    P04.06 1030 Multi-function Relay 1 disconnect delay action 0-65.5 S 0 0 P04.6 1030
    P04.07 1031 Multi-function Relay 1 Action close Delayed 0-65.5 S 0 0 P04.7 1031
    P04.08 1032 Multi-function Relay 1 disconnect delay action 0-65.5 S 0 0 P04.8 1032
    P04.09 1033 Stall rotor detection time 0-65.5 S 1 1 P04.9 1033
    P04.10 1034 Switch amount (Di) sampling time 0-1000mS 8 24 24 P04.10 1034
    P04.11 1035 Stopping Mode 0:Decelerating stop 0 0 P04.11 1035
    1:Coasting stop
    P05.00 1280 PID Output Upper limit frequency 50 50 P05.0 1280
    P05.01 1281 PID Output lower limit frequency 25 25 P05.1 1281
    P05.02 1282 PID Given Source 0 0 P05.2 1282
    P05.03 1283 PID Values Given 0.2 0.2 P05.3 1283
    P05.04 1284 PID Output characteristic(FOR /REV) 0 0 P05.4 1284
    P05.05 1285 PID Output characteristic (FOR/REV) 0 0 P05.5 1285
    P05.06 1286 PID Proportional Gain 0-100.0 50 50 P05.6 1286
    P05.07 1287 PID Integration Time Ti 0-100.0 0-100.0 50 50 P05.7 1287
    P05.08 1288 PID Derivative Time Td 0-100.0 0-100.0 50 50 P05.8 1288
    P05.09 1289 PID Deviation Limit 0-50.0 5 5 P05.9 1289
    P05.10 1290 PID Integral upper limit 50 50 P05.10 1290
    P05.11 1291 PID Given Change Time 0-600.0 1 1 P05.11 1291
    P05.12 1292 PID Feedback Filter Time 0 0 P05.12 1292
    P06.00 1536 Acceleration Time 0  0 P06.0 1536
    P06.01 1537 Accel.Time 1 0.1-6553.5 5.0 9  5.0 5 P06.1 1537
    P06.02 1538 Decel. Time 1 0.1-6553.5 5.0 8.6  5.0 5 P06.2 1538
    P06.03 1539 Accel.Time 2 0.1-6553.5 0.1-6553.5 2 2 P06.3 1539
    P06.04 1540 Decel. Time 2 0.1-6553.5 0.1-6553.5 2 2 P06.4 1540
    P06.05 1541 Accel.Time 3 0.1-6553.5 0.1-6553.5 2 2 P06.5 1541
    P06.06 1542 Decel. Time 3 0.1-6553.5 0.1-6553.5 2 2 P06.6 1542
    P06.07 1543 Accel.Time 4 0.1-6553.5 0.1-6553.5 2 2 P06.7 1543
    P06.08 1544 Decel. Time 4 0.1-6553.5 0.1-6553.5 2 2 P06.8 1544
    P06.09 1545 Accel.Time 5 0.1-6553.5 0.1-6553.5 2 2 P06.9 1545
    P06.10 1546 Decel. Time 5 0.1-6553.5 0.1-6553.5 2 2 P06.10 1546
    P06.11 1547 Accel.Time 6 0.1-6553.5 0.1-6553.5 2 2 P06.11 1547
    P06.12 1548 Decel. Time 6 0.1-6553.5 0.1-6553.5 2 2 P06.12 1548
    P06.13 1549 Accel.Time 7 0.1-6553.5 0.1-6553.5 2 2 P06.13 1549
    P06.14 1550 Decel. Time 7 0.1-6553.5 0.1-6553.5 2 2 P06.14 1550
    P06.15 1551 Accel.Time 8 0.1-6553.5 0.1-6553.5 2 2 P06.15 1551
    P06.16 1552 Decel. Time 8 0.1-6553.5 0.1-6553.5 2 2 P06.16 1552
    P06.17 1553 Jog Acceleration Time 0.1-6553.5 0.1-6553.5 2 2 P06.17 1553
    P06.18 1554 Jog Deceleration Time 0.1-6553.5 0.1-6553.5 2 2 P06.18 1554
    P07.00 1792 Frequency 1 0-120HZ(400HZ) 50HZ 50 50 P07.0 1792
    P07.01 1793 Frequency 2 50HZ 45 45 P07.1 1793
    P07.02 1794 Frequency 3 50HZ 40 40 P07.2 1794
    P07.03 1795 Frequency 4 50HZ 35 35 P07.3 1795
    P07.04 1796 Frequency 5 50HZ 30 30 P07.4 1796
    P07.05 1797 Frequency 6 50HZ 25 25 P07.5 1797
    P07.06 1798 Frequency 7 50HZ 20 20 P07.6 1798
    P07.07 1799 Frequency 8 50HZ 15 15 P07.7 1799
    P07.08 1800 Frequency source selection 1 0: Operator board (parameter: P03.06~P03.09) 0 0 P07.8 1800
    P07.09 1801 Frequency source selection 2 1: Pre-set Freq, P00.00 Set frequency value,Operation panel keyboard,Can be set directly 2 2 P07.9 1801
    P07.10 1802 Frequency source selection 3 2:No. X paragraph frequency P07.00~P07.07 2 2 P07.10 1802
    P07.11 1803 Frequency source selection 4 3: Analog Input. :P03.10~P03.13) 2 2 P07.11 1803
    P07.12 1804 Frequency source selection 5 4: external simulation amount 2 (VI2) 2 2 P07.12 1804
    P07.13 1805 Frequency source selection 6 5: (Modbus Rs485)Given frequency 2 2 P07.13 1805
    P07.14 1806 Frequency source selection 7 6: User application program, given frequency 2 2 P07.14 1806
    P07.15 1807 Frequency source selection 8 7:( Pid)Output frequency 2 2 P07.15 1807
    Other: Reserved
    Note:three control methods (P07.08) 1808 1.The motor speed is controlled by the operating panel P07.16 1808
    2.Motor speed control by external terminals (Potentiometer 10K). P00.01 set to 1, P07.08 set to 3
    3.Motor speed control by external terminals. P00.01 set to 1,P07.08 set to 1.
    P07.16 1809 Jogging Frequency FORWARD 0-120HZ(400HZ) 15.0HZ 15 P07.17 1809
    P07.17 2048 Jogging Frequency REV 0-120HZ(400HZ) 15.0HZ 13.0Hz 13 P08.0 2048
    P08.00 2049 Automatic many paragraph Running: Running direction Binary data format to set the direction of operation, see (the automatic multi segment operation, the operation of the direction set table) 0  0 P08.1 2049
    P08.01 2050 Automatic many paragraph Running: mode Choice 0:Automatic multi segment operation is invalid; 0 0 P08.2 2050
    1:After execution complete,Stop;
    2:After execution complete,Keep the last running state,Continued running;
    3:After execution complete, Repeated execution.
    P08.02 2051 Automatic many paragraph Running time Units:S/M 0:S;1:M 0 0 P08.3 2051
    P08.03 2052 Automatic many paragraph Running: No.1 paragraph Running time Automatic multi-section run time,Set up Section speed run time。Time units are determined by P08.02 Decision。Set run is 0,Indicates that this section is not executed. 10 1 1 P08.4 2052
    P08.04 2053 Automatic many paragraph Running: No.2 paragraph Running time 10 1.5 1.5 P08.5 2053
    P08.05 2054 Automatic many paragraph Running: No.3 paragraph Running time 10 1 1 P08.6 2054
    P08.06 2055 Automatic many paragraph Running: No.4 paragraph Running time 10 1.5 1.5 P08.7 2055
    P08.07 2056 Automatic many paragraph Running: No.5 paragraph Running time 10 1 1 P08.8 2056
    P08.08 2057 Automatic many paragraph Running: No.6 paragraph Running time 10 1.5 1.5 P08.9 2057
    P08.09 2058 Automatic many paragraph Running: No.7 paragraph Running time 10 1 1 P08.10 2058
    P08.10 2304 Automatic many paragraph Running: No.8 paragraph Running time 10 1.5 1.5 P09.0 2304
    P09.00 2305 frequency Range(%) 0-200% 0 0 P09.1 2305
    P09.01 2306 frequency wave Range(%) 0-400% 200 30 30 P09.2 2306
    P09.02 2307 frequency Rise time(S) 0.1-999.9 S 6.0 S 6 P09.3 2307
    P09.03 2560 frequency decline time(S) 0.1-999.9 S 5.0 S 5 P10.0 2560
    P10.00 2561 Counter reload,value 1000 1000 P10.1 2561
    P10.01 2562 Counter current value 0 0 P10.2 2562
    P10.02 2563 Timer reload,value 1000 1000 P10.3 2563
    P10.03 2816 Timer current value 0 0 P11.0 2816
    P11.00 2817 Output Status 1 1 P11.1 2817
    P11.01 2818 Output Voltage (V) 0 0 P11.2 2818
    P11.02 2819 Output Current (A) 5 5 P11.3 2819
    P11.03 2820 Output Frequency (Hz) 50 50 P11.4 2820
    P11.04 3072 Current Heatsink Temperature 25 25 P12.0 3072
    P12.00 3073 Rated Motor Current 5 5 P12.1 3073
    P12.01 3074 Rated Motor Voltage 220 220 P12.2 3074
    P12.02 3075 Motor Pole number 2-100 2 2 P12.3 3075
    P12.03 3076 Motor no-load current 10 10 P12.4 3076
    P12.04 3077 Motor no-load current detection time(S) 10 10 P12.5 3077
    P12.05 3078 Converter rated current(A) 5 5 P12.6 3078
    P12.06 3079 Converter rated Voltage(V) 220 220 P12.7 3079
    P12.07 3080 DC bus output voltage% 140 130 P12.8 3080
    P12.08 3081 Heat sink over temperature protection point 70 75 P12.9 3081
    P12.09 3082 Radiating fin temperature sensor configuration 1 1 P12.10 3082
    P12.10 3083 Abnormal reset implement wait time 120 120 P12.11 3083
    P12.11 3084 Fan Function Pattern 0:Motor running tine, start fan; 1 1 P12.12 3084
    1:When the fan operating temperature (P12.12) is exceeded,Instant start fan; When the temperature is lower than the fan temperature point,Delay about 1 minutes to close the fan;
    2:Unconditional forced start fan;
    3:Fan Inoperation;
    P12.12 3085 Cooling fan operating temperature 55 45 50 P12.13 3085
    P12.13 3086 Fan Testing 0 0 P12.14 3086
    P12.14 3087 Bypass relay closed detection 0 0 P12.15 3087
    P12.15 3088 Bypass Relay delay time 1.5 1 P12.16 3088
    P12.16 3089 Power on delay timer initial value(S) 50 50 P12.17 3089
    P12.17 3090 Electric current sensor To configure 1 1 P12.18 3090
    P12.18 3091 Automatic stable pressure function Choice 1 1 P12.19 3091
    P12.19 3092 PWM Frequency 2.0-15.0KHZ (110V13.0KHZ 220V11.0KHZ 380V6.0KHZ) 8.0KHZ 13.0KHz 13 P12.20 3092
    P12.20 3328 SVPWM Pattern 0:Three-phase asynchronous motor, 0 0 P13.0 3328
    1:Two-phase asynchronous motor (Single-phase motor, 90 degree phase difference,Starting capacitor)
    P13.00 3329 103 P13.1 3329
    P13.01 3330 600 P13.2 3330
    P13.02 3331 1 P13.3 3331
    P13.03 3332 16.24 P13.4 3332
    P13.04 3333 1 P13.5 3333
    P13.05 3584 0 P14.0 3584
    P14.00 3585 35 P14.1 3585
    P14.01 3586 0.2 P14.2 3586
    P14.02 3587 1 P14.3 3587
    P14.03 3588 0 P14.4 3588
    P14.04 3589 0 P14.5 3589
    P14.05 3590 100 P14.6 3590
    P14.06 3591 1900 P14.7 3591
    P14.07 3592 2000 P14.8 3592
    P14.08 3593 59999 P14.9 3593
    P14.09 3594 5 P14.10 3594
    P14.10 3595 20 P14.11 3595
    P14.11 3596 0 P14.12 3596
    P14.12 3597 0 P14.13 3597
    P14.13 3598 0 P14.14 3598
    P14.14 3599 0 P14.15 3599


    Additional Information:
    Sorry, that is a paste from a spread sheet, you may have to do some formatting or paste it into a spread sheet to see it better...

    Additional Information:
    I will definitely do that. Thank you so much for providing the information!!

    Additional Information:
    I also have this problem with a yl620. Is there a solution?

    Additional Information:
    Is there a wiring diagram for the 110v units. My came with a 220 volt booklet.

    Additional Information:
    my unit also came with instructions for a 220 unit. I need a 110 wiring diagram.

    Additional Information:
    These instructions are lame at best, a friend of mine ordered one of these to install on a knife grinder that I built for him, and I proceeded to setup the unit, upon connecting it to the motor, it runs the motor, but hunt's at the lower speeds, and the setting I am looking for just isn't in the list, there's some settings in the 14's that don't say what there for, can anyone help?

    Click the link to add information to this solution:
    I received a VFD 110v yl600-2s-2k20 p 110v with 220v instructions, also the connectors on the VFD dose not match any wiring configuration you have.

  • I need wiring diagram for motor to driver to usb motion card. I cannot find diagram. I have been unable to get information for a week.
  • [575] I have a 64 bit Windows 11 laptop. Will this interface board work with this? If not is there an option you can suggest.

    Yes, the Mach3 USB controller will work with the latest Windows version and in 64-bit mode. The 32-bit mode is only relevant for using the parallel port driver if you are using a parallel port breakout board. Since this controller is connected via a USB cable, the 64-bit state will work fine.

    Click the link to add information to this solution:
    [575] I have a 64 bit Windows 11 laptop. Will this interface board work with this? If not is there an option you can suggest.

  • I need the drive setting for the 1.5kw spindle drive to work with the spindle motor where do I find them

    If you purchased the spindle from us, you should have received a little booklet that shows all of the program settings. If you did not receive that booklet, please call us so we can send you this booklet.

    If you have the booklet, please let us know specifically what setting you would like to set and we can help.

    Click the link to add information to this solution:
    I need the drive setting for the 1.5kw spindle drive to work with the spindle motor where do I find them

  • I purchased the greenbull with the electronics assembled, where are the wiring schematics to wire to 110 volt inverter?

    There is another image on the spindle page here that shows another type of wiring using the R, T and E terminals for power. The image is one of the clickable main images on that page:

    https://www.buildyourcnc.com/item/spindle-inverter-2!2kw-spindle-novfd

    Additional Information:
    Here is a link to the image directly:

    https://www.buildyourcnc.com/images/SpindleWiring-800.JPG

    And here is the link to the alternate diagram:

    https://www.buildyourcnc.com/images/NewSpindleDiagram-800.JPG

    Click the link to add information to this solution:
    I purchased the greenbull with the electronics assembled, where are the wiring schematics to wire to 110 volt inverter?

  • I have a water cooled spindle I only need the VFD drive. Does the VFD come with instrutction on hooking the VFD to Mach3?

    The VFD does come with a manual that details the wiring and connection specifications, terminal features and a list of the parameters. There is no information on how to connect it to Mach3. It does detail the specifications within the parameters and terminal features on the analog input that is used with Mach3 and other control programs.

    Click the link to add information to this solution:
    I have a water cooled spindle I only need the VFD drive. Does the VFD come with instrutction on hooking the VFD to Mach3?

  • Do you have a larger kit for the Blacktooth Laser? I need a laser with at least 80watts of power.

    We have one in the works. It is a 4'x8' machine that will house the 80w laser tube on the gantry. The machine is bout 2 months out as of 1/7/2014.

    Additional Information:



    Additional Information:



    Additional Information:

    Click the link to add information to this solution:
    Do you have a larger kit for the Blacktooth Laser? I need a laser with at least 80watts of power.

  • For our cnc we're searching for an air cooled spindle with 2.2 kw. On this page we've only found water cooled ones. Is it possible to get an air cooled spindle from you or do you have special reasons for don't selling them?

    We like the water cooled spindles since they don't blow the chips around the shop. The air cooled spindles have a force of air that partly makes the vacuum and dust shoe non effective, unless we design a diverter, which limits the cooling effect for the spindle.

    Click the link to add information to this solution:
    For our cnc we're searching for an air cooled spindle with 2.2 kw. On this page we've only found water cooled ones. Is it possible to get an air cooled spindle from you or do you have special reasons for don't selling them?

  • How do I determine what post processor I have on my shop built CNC. There are about a million to choose from on Vcarve Pro

    You will probably have post processors like the following listed:
    Mach2/3 ATC Arcs (inch)
    Mach2/3 ATC Arcs (mm)
    Mach2/3 Arcs (inch)
    Mach2/3 Arcs (mm)
    Mach2/3-WrapX2A ATC Arcs (inch)
    Mach2/3-WrapX2A ATC Arcs (mm)
    Mach2/3-WrapY2A ATC Arcs (inch)
    Mach2/3-WrapY2A ATC Arcs (mm)

    If you have an Automatic Tool Changer, use the post processor with the ATC in the name. For most applications and if you don't have an ATC (automatic tool changer), use the Mach2/3 Arcs (inch) or (mm) post processor.




    Additional Information:

    Click the link to add information to this solution:
    How do I determine what post processor I have on my shop built CNC. There are about a million to choose from on Vcarve Pro

  • I am working with a Spur gear that has a 15 tooth 3/8 bore/ 3/8 wide....is the 651ozin stepper motor compatible with this or do I need to get a different motor

    This gear should work with this motor. The shaft on the 651ozin motor is 3/8"

    Click the link to add information to this solution:
    I am working with a Spur gear that has a 15 tooth 3/8 bore/ 3/8 wide....is the 651ozin stepper motor compatible with this or do I need to get a different motor

Get Help with:
This Product
Orders
Tech Support
Sales
This Product
Order Query
Tech Support
Sales
Not logged in. Log In Register
Track Order(s)
View Order(s)
I Want to Schecule a One-On-One Paid Tech Support Session
Book an Appointment Pertaining to a BuildYourCNC Product (Free)
Ask a Quesion Below (Free):
Book an Appointment Pertaining Other Equipment ($60/half hour)
Book an Immedite Appointment Pertaining Other Equipment ($120/half hour)
Ask a Quesion Below (Free):
Waiting for response... I may not answer immediately, but I was notified on my cellular phone so my response is forthcoming. If I don't respond immediately, you can always go to the [My Account] page to see all of our chats at any time.