Question #: 14187

Question: I have a YL620 VFD and the 2.2 kw spindle. The programming that is on the buildyourcnc web site is different in the PO/PD parameters. Do you have the VFD settings for the parameters using the P00.00 format?

Current Solution

This will point you in the right direction.
http://vancura.biz/files/Documents/CNC/YL620-A%20Setup%20table%20190707.pdf

Additional Information:

Respond:

Other Possible Solutions to this Question

  • I have a YL600 VFD and the 2.2 kw spindle. The programming that is on the buildyourcnc web site is different in the PO/PD parameters. Do you have the VFD settings for the parameters using the P00.00 format0

    MY VFD SHOW E.O.C.A error


    Additional Information:
    EOCA light on my VFD


    Additional Information:


    Additional Information:

    Click the link to add information to this solution:
    I have a YL600 VFD and the 2.2 kw spindle. The programming that is on the buildyourcnc web site is different in the PO/PD parameters. Do you have the VFD settings for the parameters using the P00.00 format0

  • I HAVE A 2.2KW WATER COOLED SPINDLE WITH YL620-H VFD. THE VFD USES P#-## PROGRAM FORMAT. BELIEVE ALL CORRECT SETTINGS SETUP BUT WHEN TURN UNIT ON, IT SPINS AT ABOUT 200-300 RPM REGARDLESS OF WHAT FREQUENCY CHOOSE. DO YOU PARAMETERS IN THIS FORMAT FOR UNIT? THANK YOUR HELP. HUIBERT MEES

    You will need to look for the parameter that controls the run frequency. The frequency can be controlled bu the panel, external terminals, or the RS485 TX/RX terminals (UART protocol). You will want to change that parameter so it uses the panel. If you are referring to the maximum panel dial frequency is only allowing 200-300 rpm, then look for the parameters to control the frequency.

    For 200 RPM:
    Hz = 200/60 = 3.33 Hz

    For 300 RPM:
    Hz = 300/60 = 5 Hz

    Conversion to RPM:
    If you ever find yourself yearning to reverse-engineer the process, the formula is as follows:

    RPM = Hz × 60

    Look for values that match somewhere between 3 and 5 in your frequency parameters and replace them with 400 to give you 24,000 RPM max.

    Click the link to add information to this solution:
    I HAVE A 2.2KW WATER COOLED SPINDLE WITH YL620-H VFD. THE VFD USES P#-## PROGRAM FORMAT. BELIEVE ALL CORRECT SETTINGS SETUP BUT WHEN TURN UNIT ON, IT SPINS AT ABOUT 200-300 RPM REGARDLESS OF WHAT FREQUENCY CHOOSE. DO YOU PARAMETERS IN THIS FORMAT FOR UNIT? THANK YOUR HELP. HUIBERT MEES

  • [575] I have the wiring and programming and parameters set the same way that you do in the spindle speed control and outputs videos, I can start and stop the spindle with mach3 but can't seem to control the speed. Can you think of solutions?

    Do you have an oscilloscope? You will be able to see the PWM signal and determine if the output is correct. Make sure that you are using the 10V from the VFD as the voltage reference for the 10V terminal on the Mach3 USB controller. The 10V terminal is an input, not an output on the Mach3 USB controller. The 10V is the top voltage signal level that the Mach3 USB controller uses for the PWM signals 100% duty cycle.

    Click the link to add information to this solution:
    [575] I have the wiring and programming and parameters set the same way that you do in the spindle speed control and outputs videos, I can start and stop the spindle with mach3 but can't seem to control the speed. Can you think of solutions?

  • I have a 2.2kw water cooled spindle with a YL620-H VFD. The VFD uses the P#-## program format. I believe I have all the correct settings setup but when I turn the unit on, it spins at about 200-300 RPM regardless of what frequency I choose. Do you have the correct program parameters in this format for this unit? Thank you for your help. Huibert Mees

    You will need to look for the parameter that controls the run frequency. The frequency can be controlled bu the panel, external terminals, or the RS485 TX/RX terminals (UART protocol). You will want to change that parameter so it uses the panel. If you are referring to the maximum panel dial frequency is only allowing 200-300 rpm, then look for the parameters to control the frequency.

    For 200 RPM:
    Hz = 200/60 = 3.33 Hz

    For 300 RPM:
    Hz = 300/60 = 5 Hz

    Conversion to RPM:
    If you ever find yourself yearning to reverse-engineer the process, the formula is as follows:

    RPM = Hz × 60

    Look for values that match somewhere between 3 and 5 in your frequency parameters and replace them with 400 to give you 24,000 RPM max.

    Click the link to add information to this solution:
    I have a 2.2kw water cooled spindle with a YL620-H VFD. The VFD uses the P#-## program format. I believe I have all the correct settings setup but when I turn the unit on, it spins at about 200-300 RPM regardless of what frequency I choose. Do you have the correct program parameters in this format for this unit? Thank you for your help. Huibert Mees

  • I have wired up my 110v VFD and my 2.2Kw spindle and I get an E.Lu.5 code. My wiring is correct and the parameters are set to those for the VFD according to your website I found in a previously answered question from someone here. Any help would be greatly appreciated, thank you!!

    The E.Lu.5 Error code on your VFD is related to Low Voltage.

    The recommended action is:
    - 1. Check whether the input voltage is normal. (the voltage from the wall/breaker to the VFD)
    - 2. Check whether there is a sudden change in load.
    - 3. Check whether there is any phase missing.

    Unfortunately, these three recommended actions will probable require an electrician to test the line going into the VFD.

    Additional Information:

    Click the link to add information to this solution:
    I have wired up my 110v VFD and my 2.2Kw spindle and I get an E.Lu.5 code. My wiring is correct and the parameters are set to those for the VFD according to your website I found in a previously answered question from someone here. Any help would be greatly appreciated, thank you!!

  • I'VE BUFFERED A PWM SIGNAL TO 0-10V ANALOG AND I WOULD LIKE USE THAT RUN YOUR 110V 2.2KW SPINDLE VFD. COULD YOU PLEASE DETAIL THE CORRECT WIRING VFD SETTINGS GET WORKING?

    This will depend on the VFD you have to identify the correct terminal. The terminal on the VFD will be labeled AI1 typically (Analog Input #1). You will also need to make sure to complete the PWM circuit using the GND terminal on the VFD.

    Additional Information:
    I have wired my 0-10V signal to the AI1 and GND terminals as suggested. I have also set the PD-01 and PD-02 settings to 1. Still nothing. Is there something else that I am missing?

    Additional Information:
    Thanks for the information. Can you let me know the model of the VFD that you have?

    Additional Information:
    VFD Model # YL600-2S-2K20

    Additional Information:
    Thanks. I will check our resources and documentation to see if there is another programming setting that needs to be changed.

    Additional Information:
    Does your VFD have a VI terminal?

    Additional Information:
    No, it does not. The terminals for this VFD are as follows (seperated by dashes "-").

    10V-AI1-AO2-PLC-DI5-DI3-DI1-COM
    AI2-GND-AO1-DI6-DI4-DI2-FM-24V

    Additional Information:
    Do you have a PD070 parameter?

    PD070 is the main Analog Input parameter.

    The options for that parameter is:
    0: 0-10V
    1: 0-5V
    2: 0-20mA
    3: 4-20mA
    4: 0-10V (4-20mA Stacked)
    5: XIA
    6: (VI+XIA)/2
    7: (3VA+XIA)/4
    8: (XIA_XIB)/2
    9: Max (XIA, XIB)
    10: Min (XIA, XIB)


    Additional Information:
    There is a PD-00 thru PD-09. PD-07 is currently set to 0.

    Additional Information:
    It appears that the manual I’m using “Titled YL600” is not the same as your unit. I will check our manuals and find the one that has only PD-00 to PD-09.

    Additional Information:
    For that VFD, the parameters are P0. The 0 may look like a D on the display.

    The parameters that need to be changed for the AI1 to work (Brackets [] around the correct selection):

    P0-01: First Motor Control Mode
    - 0: Sensorless Vector Control
    - 1: Flux Vector Control (FVC)
    - [2]: V/F Control

    P0-02: Options of Command Source
    - 0: Operation Panel Command Channel (LED will be off)
    - [1]: Terminal Command Channel (LED will be on)
    - 2: Communication Command Channel (LED will flicker)

    P0-03: Options of Principle Frequency Source X
    - 0: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, no power-down memory)
    - 1: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, with power-down memory)
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID (Proportional Integral Derivative Control)
    - 9: Communication Given

    P0-11: Upper Limit Frequency Source
    - 0: P0-12 (Make sure the P0-12 parameter has the correct max frequency if used)
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given

    P0-27: Command Source Bundle with Frequency Sources
    Single Digit: Options of Operation Panel Command Bundle with Frequency Sources
    - 0: No Bundling
    - 1: Digital Setting Frequency
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID
    - 9: Communication Given
    Double Digit: Options of Terminal Command Bundle with Frequency Sources
    Hundred Place: Options of Communication Command Bundle with Frequency Sources
    Kilobit: Options of Automatic Operation Bundle with Frequency Sources

    P2-09: Upper Limit Source of Lower Torque Under Speed Control Mode
    - 0: Function Code P2-10 Setting
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given
    - 6: MIN (Al1, Al2)
    - 7: MAX (Al1, Al2)
    - Maximum range for options 1-7, accords with P2-10

    If you elect to use a different AI#, then configure the parameters (P0-03, P0-11, P0-27 and P2-09) accordingly.

    Click the link to add information to this solution:
    I'VE BUFFERED A PWM SIGNAL TO 0-10V ANALOG AND I WOULD LIKE USE THAT RUN YOUR 110V 2.2KW SPINDLE VFD. COULD YOU PLEASE DETAIL THE CORRECT WIRING VFD SETTINGS GET WORKING?

  • When I start my spindle I get a emergency stop in Mach 3. I have run shielded cable and it is grounded at the VFD it is wired per you site instructions. any idea what to check

    You will definitely want to adjust your debounce setting in mach3 if your emergency or limit switch is engaging.

    Additional Information:
    Did you ever fix this issue? I am having the same problem.

    Additional Information:
    Did you ever fix this issue? I am having the same problem.

    Additional Information:
    Did you ever fix this issue? I am having the same problem.

    Additional Information:
    Did you ever fix this issue? I am having the same problem.

    Additional Information:
    Did you ever fix this issue? I am having the same problem.

    Additional Information:
    Did you ever fix this issue? I am having the same problem.

    Additional Information:
    Did you ever fix this issue? I am having the same problem.

    Additional Information:
    Did you ever fix this issue? I am having the same problem.

    Additional Information:
    Did you try changing the denounce setting?

    Additional Information:
    Meant to say denounce.

    Click the link to add information to this solution:
    When I start my spindle I get a emergency stop in Mach 3. I have run shielded cable and it is grounded at the VFD it is wired per you site instructions. any idea what to check

  • I have the 2.2 kW spindle and VFD for 110v, just wondering what amperage this draws, as my electricain buddy is telling me I need to put in a 20 amp breaker for this. I cant seem to find any amerpage draw on the INPUT label

    You can actually set a current limit in in the VFD using the programming process and the specifications in the manual that came with your VFD. You can expect the spindle at 220 Volts AC to draw (using the standard formula):

    For Volts, I will use 230 as the range is generally 220 to 240.

    Watts = Current * Volts

    Can also be written as:

    Current = Watts / Volts

    Current = 2.2kW (2200 watts) / 230 volts

    Current = 9.6 amps

    Click the link to add information to this solution:
    I have the 2.2 kW spindle and VFD for 110v, just wondering what amperage this draws, as my electricain buddy is telling me I need to put in a 20 amp breaker for this. I cant seem to find any amerpage draw on the INPUT label

  • How do I get Homing on Z to work with Plate and Ground using Buildyourcnc usb board all the entries for the sensor in planet-cnc are grayed out. I am using input z- and I purchased the software

    To home the z-axis using a plate:
    - Connect the end mill using a large clamping device like an alligator clip with a wire connected to GND.

    - Connect the plate (solder a wire to the plate) to one of the input pins.

    - You can use the autoset to setup that pin in Mach3 simply by touching the two together once connected to the pin and GND.

    Alternatively, the end mill can be connected to the pin and the plate connected to GND as long as there becomes a complete circuit when the end mill touches the plate.

    To setup homing for the Planet-CNC homing and limits, go to the Planet-CNC Machine setup page which explains the process step by step: http://www.planet-cnc.com/faq/machine_setup/

    Customer Response:
    How do I get homing on z to work with planet cnc software using build your own usb board. I have gone to planet website and followed the instructions provided but my software will not allow entries in the required fields they are grayed out is it because I am not using planet-cnc's board, I have used this method for years with Mach3 and would like to use it with the usb board and software.

    Answer:
    Just received information from the developer. The instructions on how to use a plate for z-axis homing (moveable sensor) can be found here:

    http://www.planet-cnc.com/faq/moveable_sensor/

    Click the link to add information to this solution:
    How do I get Homing on Z to work with Plate and Ground using Buildyourcnc usb board all the entries for the sensor in planet-cnc are grayed out. I am using input z- and I purchased the software

  • What are the configuration settings for VFD for Spindle 1.5kW 110V. The search settings have a link for a 2.2kw spindle so I'm afraid they are the wrong ones and I don't want to fry the spindle. My VFD is an Huanyang HY01D511B.

    Did you get a manual for your VFD? Where did you purchase the VFD and spindle?

    Additional Information:
    I bought the VFD through Amazon with a similar spindle that you sell. The VFD came with a manual but unfortunately the spindle had all the model number and specs scratched off of it. In an attempt to set it up, I fried the spindle. I have complained to the vendor and to Amazon but have received no solution. If your spindle arrives with proper documentation I probably can set it up myself.

    Click the link to add information to this solution:
    What are the configuration settings for VFD for Spindle 1.5kW 110V. The search settings have a link for a 2.2kw spindle so I'm afraid they are the wrong ones and I don't want to fry the spindle. My VFD is an Huanyang HY01D511B.

  • I have a blueChick 13"x24" or 13"x36" Desktop CNC Router Kit v3.0 (Timing Belt) that I've assembled but never was able to get it running. Can BuildYourCNC assist me in selling this machine? Do you have used machine offerings on your site?

    We would highly recommend using our forums to sell you machine buildyourtools.com.
    We currently do not have a page or option to allow our customers to sell our machines, you can also contact us at customerservice@buildyourcnc.com, for further assistance dealing with the machine and in regards to selling it.

    Click the link to add information to this solution:
    I have a blueChick 13"x24" or 13"x36" Desktop CNC Router Kit v3.0 (Timing Belt) that I've assembled but never was able to get it running. Can BuildYourCNC assist me in selling this machine? Do you have used machine offerings on your site?

  • I've buffered a PWM signal to a 0-10V analog signal and I would like to use that signal to run your 110V 2.2kW spindle and VFD. Could you please detail the correct wiring and VFD settings to get that working?

    This will depend on the VFD you have to identify the correct terminal. The terminal on the VFD will be labeled AI1 typically (Analog Input #1). You will also need to make sure to complete the PWM circuit using the GND terminal on the VFD.

    Additional Information:
    I have wired my 0-10V signal to the AI1 and GND terminals as suggested. I have also set the PD-01 and PD-02 settings to 1. Still nothing. Is there something else that I am missing?

    Additional Information:
    Thanks for the information. Can you let me know the model of the VFD that you have?

    Additional Information:
    VFD Model # YL600-2S-2K20

    Additional Information:
    Thanks. I will check our resources and documentation to see if there is another programming setting that needs to be changed.

    Additional Information:
    Does your VFD have a VI terminal?

    Additional Information:
    No, it does not. The terminals for this VFD are as follows (seperated by dashes "-").

    10V-AI1-AO2-PLC-DI5-DI3-DI1-COM
    AI2-GND-AO1-DI6-DI4-DI2-FM-24V

    Additional Information:
    Do you have a PD070 parameter?

    PD070 is the main Analog Input parameter.

    The options for that parameter is:
    0: 0-10V
    1: 0-5V
    2: 0-20mA
    3: 4-20mA
    4: 0-10V (4-20mA Stacked)
    5: XIA
    6: (VI+XIA)/2
    7: (3VA+XIA)/4
    8: (XIA_XIB)/2
    9: Max (XIA, XIB)
    10: Min (XIA, XIB)


    Additional Information:
    There is a PD-00 thru PD-09. PD-07 is currently set to 0.

    Additional Information:
    It appears that the manual I’m using “Titled YL600” is not the same as your unit. I will check our manuals and find the one that has only PD-00 to PD-09.

    Additional Information:
    For that VFD, the parameters are P0. The 0 may look like a D on the display.

    The parameters that need to be changed for the AI1 to work (Brackets [] around the correct selection):

    P0-01: First Motor Control Mode
    - 0: Sensorless Vector Control
    - 1: Flux Vector Control (FVC)
    - [2]: V/F Control

    P0-02: Options of Command Source
    - 0: Operation Panel Command Channel (LED will be off)
    - [1]: Terminal Command Channel (LED will be on)
    - 2: Communication Command Channel (LED will flicker)

    P0-03: Options of Principle Frequency Source X
    - 0: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, no power-down memory)
    - 1: Digital Setting (Preset Frequency P0-08, UP/DOWN modifiable, with power-down memory)
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID (Proportional Integral Derivative Control)
    - 9: Communication Given

    P0-11: Upper Limit Frequency Source
    - 0: P0-12 (Make sure the P0-12 parameter has the correct max frequency if used)
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given

    P0-27: Command Source Bundle with Frequency Sources
    Single Digit: Options of Operation Panel Command Bundle with Frequency Sources
    - 0: No Bundling
    - 1: Digital Setting Frequency
    - [2]: AI1
    - 3: AI2
    - 4: AI3
    - 5: Pulse Setting (DI5)
    - 6: Multi Speed Instruction
    - 7: Simple PLC
    - 8: PID
    - 9: Communication Given
    Double Digit: Options of Terminal Command Bundle with Frequency Sources
    Hundred Place: Options of Communication Command Bundle with Frequency Sources
    Kilobit: Options of Automatic Operation Bundle with Frequency Sources

    P2-09: Upper Limit Source of Lower Torque Under Speed Control Mode
    - 0: Function Code P2-10 Setting
    - [1]: AI1
    - 2: AI2
    - 3: AI3
    - 4: Pulse Setting
    - 5: Communication Given
    - 6: MIN (Al1, Al2)
    - 7: MAX (Al1, Al2)
    - Maximum range for options 1-7, accords with P2-10

    If you elect to use a different AI#, then configure the parameters (P0-03, P0-11, P0-27 and P2-09) accordingly.

    Click the link to add information to this solution:
    I've buffered a PWM signal to a 0-10V analog signal and I would like to use that signal to run your 110V 2.2kW spindle and VFD. Could you please detail the correct wiring and VFD settings to get that working?

  • [575] Can you please point me in the direction of a list of VFD Parameters for this to as intended for spindle speed control? I’m using Hunyang VFD. I’ve verified outputs/relays working as intended and PWM signal is correct at the VFD, but its still pulling speed control from the onboard pot instead of PWM signal. I’ve tried every combination of parameters I can think of but no luck.

    The HY VFD has three main terminals for PWM control. These terminal inputs are:
    - VI for the analog (PWM) voltage input (input at the VFD, output at the controller, i.e. the Mach3 USB controller),
    - 10V output (this is an output from the VFD and an input at the controller) serves as the high voltage value for the width of the voltage,
    - and ACM the ground from the controller (DCM at the controller)

    In the parameters:
    - PD002 should be set to 1 (one). PD002 is the source of operating frequency which is the RPM of the spindle in the Hz frequency units. 400Hz = 24000 RPM.
    - PD003 specifies the frequency range for these terminals (10V, VI, and ACM) where 10V (voltage reference) is 400Hz and 0v is 0Hz, and VI adjusts the range from 0 and the voltage reverence (10V).
    - PD070 selects the voltage range or current range (for use with the AI external VFD terminal as opposed to using the VI). You want to keep that parameter at the factory setting of 0 (zero) 0-10V.

    Click the link to add information to this solution:
    [575] Can you please point me in the direction of a list of VFD Parameters for this to as intended for spindle speed control? I’m using Hunyang VFD. I’ve verified outputs/relays working as intended and PWM signal is correct at the VFD, but its still pulling speed control from the onboard pot instead of PWM signal. I’ve tried every combination of parameters I can think of but no luck.

  • I purchased the 4.0kw spindle and VFD a while back, and have just installed a PMDX-107 controller... do you have any examples of the wiring connections for the SL-240EE to PMDX-107?

    If you want speed control, it is recommended to use the RS-485 connection on the VFD and use the control program such as Mach3 to communication serially with the VFD using this RS-485 connection.

    If you would rather use a controller such as the PMDX-107 to simulate the effect of a potentiometer using the Aref, Aout and Agnd and the Rev/Dir and Fwd/Run terminals to control operation and direction, you can connect those to the VFD.

    PMDX-107 Aout connects to the VI (analog voltage in). This is like the wiper on a potentiometer.
    PMDX-107 Agnd connects to the ACM terminal on the VFD for Analog common.
    PMDX-107 COM connects to DCM terminal on the VFD for Digital common.
    PMDX-107 Fwd/Run connects to the FOR terminal on the VFD for Forward.
    PMDX-107 Rev/Dir connects to the REV terminal on the VFD for Reverse.

    Refer to your PMDX-107 manual to correctly configure your dip switch settings and make sure to calibrate (tweak) the speed control using the trimmer next to the terminals on the PMDX-107.

    Click the link to add information to this solution:
    I purchased the 4.0kw spindle and VFD a while back, and have just installed a PMDX-107 controller... do you have any examples of the wiring connections for the SL-240EE to PMDX-107?

  • I WIRED MY VFD (2.2KW VERSION) AND TRIED TEST RUNNING THE SPINDLE. CONFIGURED TO YOUR SPECS ON THIS WEBSITE, ONLY ISSUE IS WE GOT AN ERROR CODE. ERR 02, DO YOU KNOW WHAT IS? OR HAVE A LIST OF CODES? THANK

    Can you provide the model number of your VFD?

    Yes, I have the "YL600 - 2S - 2K20"

    It just came with a small booklet that is all in Chinese...

    Click the link to add information to this solution:
    I WIRED MY VFD (2.2KW VERSION) AND TRIED TEST RUNNING THE SPINDLE. CONFIGURED TO YOUR SPECS ON THIS WEBSITE, ONLY ISSUE IS WE GOT AN ERROR CODE. ERR 02, DO YOU KNOW WHAT IS? OR HAVE A LIST OF CODES? THANK

  • [77] Hello. I’m interested in buying a water cooled spindle and VFD. I have an Avid Pro CNC and would love to control it using Mach 4 but I keep hearing it’s difficult to integrate. Also, is the water pump 120 or 240? I’d love any advice etc. eBay is a web of confusion with all of the options. Thank you.

    You will need to look for the parameter that controls the run frequency. The frequency can be controlled bu the panel, external terminals, or the RS485 TX/RX terminals (UART protocol). You will want to change that parameter so it uses the panel. If you are referring to the maximum panel dial frequency is only allowing 200-300 rpm, then look for the parameters to control the frequency.

    For 200 RPM:
    Hz = 200/60 = 3.33 Hz

    For 300 RPM:
    Hz = 300/60 = 5 Hz

    Conversion to RPM:
    If you ever find yourself yearning to reverse-engineer the process, the formula is as follows:

    RPM = Hz × 60

    Look for values that match somewhere between 3 and 5 in your frequency parameters and replace them with 400 to give you 24,000 RPM max.

    Click the link to add information to this solution:
    [77] Hello. I’m interested in buying a water cooled spindle and VFD. I have an Avid Pro CNC and would love to control it using Mach 4 but I keep hearing it’s difficult to integrate. Also, is the water pump 120 or 240? I’d love any advice etc. eBay is a web of confusion with all of the options. Thank you.

  • HEY ! I HAVE PURCHASED A VFD WITH MATCHING SPINDLE 1.5KW AND CONTROL PROGRAM UCCNC. MY INTERFACE CARD IS DB25, THE QUESTION HOW DO CONNECT TO DB25 SO THAT CAN SPEED UCCNC? SINCERELY "CNC BEGINNERS"

    Identify the Control Signals: First, determine which control signals from the DB25 interface card are used for spindle speed control. Typically, these are PWM (Pulse Width Modulation) signals or analog voltage signals.

    VFD Configuration: Your VFD should be configured to accept the type of control signal your DB25 card provides. This involves setting parameters in the VFD that correspond to the type of input signal it will receive for speed control.

    Wiring: Connect the appropriate output pins from the DB25 card to the input terminals on the VFD. This usually involves connecting the PWM or analog output to the corresponding input on the VFD. Make sure to consult the manuals for both your VFD and interface card for specific wiring details.

    UCCNC Settings: Configure UCCNC to output the correct type of signal (PWM or analog) that matches your VFD's configuration. This is done through the software's spindle setup section.

    Test and Adjust: Run some tests to ensure that the spindle speed is being correctly controlled by UCCNC. You might need to tweak settings in either the VFD or UCCNC for optimal performance.

    Click the link to add information to this solution:
    HEY ! I HAVE PURCHASED A VFD WITH MATCHING SPINDLE 1.5KW AND CONTROL PROGRAM UCCNC. MY INTERFACE CARD IS DB25, THE QUESTION HOW DO CONNECT TO DB25 SO THAT CAN SPEED UCCNC? SINCERELY "CNC BEGINNERS"

  • I purchased the blackTooth Laser Engraver with integrated Laser Control Unit and have been following your instructions. I noticed that the laser tube power supply is different that what is shown in your instructions. Do you have any better wiring guides that I can follow for the version that I received?

    There is some variation in the outward appearance of laser power supplies due to sourcing through different vendors. However, the basic wiring requirements are the same in each case. For the unit with integrated laser controller, follow the diagram found here: https://buildyourcnc.com/blackToothLaserCutterAndEngraver.aspx#prettyPhoto/0/. The terminals on the signal side will have a 6 connection terminal block -- these are the ones labeled 5V, IN, G, P (or WP), L (or TTL-L), and H (or TTL-H). The High Power side will have 3 inputs for AC power, one high voltage lead, and one return line. Connect these as shown in the diagram as well: the return line goes on the "front" (beam exit end) terminal of the laser tube, the high voltage lead goes to the "back" terminal of the tube, the FG terminal (or G) receives the earth ground wire of the AC power cable, and the two AC terminals receive the line and neutral wires of the AC power cable (it doesn't matter in this case which wire goes to which terminal).

    Click the link to add information to this solution:
    I purchased the blackTooth Laser Engraver with integrated Laser Control Unit and have been following your instructions. I noticed that the laser tube power supply is different that what is shown in your instructions. Do you have any better wiring guides that I can follow for the version that I received?

  • I wired my vfd (2.2kw version) and tried test running the spindle. I configured to your specs on this website, only issue is we got an error code. Err 02, do you know what this is? OR have a list of error codes? Thank you

    Can you provide the model number of your VFD?

    Yes, I have the "YL600 - 2S - 2K20"

    It just came with a small booklet that is all in Chinese...

    Click the link to add information to this solution:
    I wired my vfd (2.2kw version) and tried test running the spindle. I configured to your specs on this website, only issue is we got an error code. Err 02, do you know what this is? OR have a list of error codes? Thank you

Get Help with:
This Product
Orders
Tech Support
Sales
This Product
Order Query
Tech Support
Sales
Not logged in. Log In Register
Track Order(s)
View Order(s)
I Want to Schecule a One-On-One Paid Tech Support Session
Book an Appointment Pertaining to a BuildYourCNC Product (Free)
Ask a Quesion Below (Free):
Book an Appointment Pertaining Other Equipment ($60/half hour)
Book an Immedite Appointment Pertaining Other Equipment ($120/half hour)
Ask a Quesion Below (Free):
Waiting for response... I may not answer immediately, but I was notified on my cellular phone so my response is forthcoming. If I don't respond immediately, you can always go to the [My Account] page to see all of our chats at any time.